TrueSpeech® Co-Processor
PRELIMINARY/CONFIDENTIAL
Version: 1.18
Example 3: Linear 16-bit Playback via Host Transmit Data Buffer Access Port - Using DMA
This example shows how to start playback in uncompressed 16-bit Linear Format Speech with data transfers
performed via the Host Transmit Data Buffer Access Port. An external DMA controller performs all data transfers
in this example.
Starting Playback
1. CT8022 is in IDLE state or RECORD state.
2. Host checks for CONTROL READY state in Hardware Status Register.
3. Host selects Poll Sync Mode for playback using the command 5202H.
4. CT8022 responds via the Software Status Register.
5. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register. This clears the STATUS READY bit.
6. Host selects Playback by issuing the PLAYBACK C1 command = 2C63H or 2C61H (PLAYMODE = [binary]
110) via the Software Control Register. This also informs the CT8022 that data transfers will occur via the Host
Transmit Data Buffer Access Port (TFR Mode = [binary] 11 or 01).
7. CT8022 responds via the Software Status Register after a delay of up to 2 speech frame periods.
8. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register S1 = 2C63H or 2C61H. This clears the STATUS READY bit.
9. Host writes PLAYBACK C2 command = 2000H to the Software Control Register.
10. CT8022 responds via the Software Status Register.
11. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register S2 = 2000H. This clears the STATUS READY bit.
12. Host writes PLAYBACK C3 command = 20F0H to the Software Control Register. This command includes the
requested number of words per frame to transfer. In this case (uncompressed 16-bit linear) this is 240 = F0H.
13. CT8022 responds via the Software Status Register.
14. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register S3 = 2000H. This clears the STATUS READY bit. The S3 response sets the
actual number of words to transfer to 00H. This transfer count indicates the number of words to be transferred
via the Software Control and Status Registers. Since this example uses TFR Mode = [binary] 11, no data is
transferred via the Software Control and Status Registers, instead the data transfer takes place via the Host
Transmit Data Buffer Access Port.
15. Host programs external DMA controller to accept DMA requests from the CT8022 (See DMA Direction bit in
Hardware Control Register). Host configures a data buffer in the Host memory to store the speech data ready
for DMA. The DMA memory buffer should be an integral multiple of the speech frame size. In the case of
uncompressed 16-bit Linear, this should be N*480 (bytes).
16. Host sets up an ISR to handle an end-of-transfer (EOT) interrupt from the DMA controller when it reaches the
end of the DMA buffer. Alternatively, if the DMA supports circular-buffering (auto-initialize), the Host can
poll the DMA to determine when the end of the buffer is reached.
17. Host programs the Hardware Control Register to generate a DMA request from the CT8022 on the TX Ready
condition by writing 00A0H ( TX DMA Burst Mode, TX DMA enable) - or 01A0H (TX DMA Burst Mode,
TX DMA enable, DMA Direction bit set).
18. The CT8022 is now in playback mode. The CT8022 will consume an uncompressed speech frame every 30ms.
The following sequence occurs between the CT8022 and the DMA controller to transfer data:
a. CT8022 is ready to receive 240 words (480 bytes) of uncompressed 16-bit speech data.
b. CT8022 asserts TX Ready.
c. TX Ready drives TXDREQ.
d. DMA controller responds to TXDREQ by asserting TXDACKN.
e. DMA controller performs a burst transfer of 16 words (32 bytes) from the Host DMA memory buffer to the
CT8022.
f. CT8022 de-asserts TX Ready.
g. CT8022 transfers 16 words from the Host Transmit Data Buffer into its internal playback buffer.
h. Repeat b-g until all 240 words of the speech data frame have been transferred.