English
Language : 

CT8022 Datasheet, PDF (74/194 Pages) List of Unclassifed Manufacturers – VOIP/VON G.723.1, G279AB TRUESPEECH CO-PROCESSOR
TrueSpeech® Co-Processor
PRELIMINARY/CONFIDENTIAL
Version: 1.18
Terminating Playback:
1. Host writes IDLE = 0000H command or STOP PLAYBACK = 5220H command to the Software Control
Register.
2. CT8022 terminates playback, discards data in its internal playback buffer, and clears TX Ready if set (in the
Hardware Status Register).
3. CT8022 writes status response to the Software Status Register.
4. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register. This clears the STATUS READY bit.
When either the Idle or Stop Playback command is used to terminate playback, the CT8022 will discard data in its
internal playback buffer. In some cases, this may not be desired. For example, when playing back TrueSpeech 6.3
data stored in a disk file, if either the Idle or Stop Playback command is issued immediately at end-of-file (EOF), the
last 20 frames (600ms) of the message will not be played. The Host may wish to use the playback Buffer
Monitoring command (5212H). With command, the Host can poll the CT8022 and wait until all the internally
stored speech data has been played out before issuing the Idle or Stop Playback command.
Note: After writing the Idle or Stop Playback command to terminate playback, the Host should not attempt
to access the Host Transmit Data Buffer Access Port even if the TX Ready bit is set.
Example 2: TrueSpeech 5.3 Playback via Host Receive Data Buffer Access Port - Host Interrupt
This example shows how to start playback with TrueSpeech 5.3 using data transfers performed via the Host Transmit
Data Buffer Access Port. The Host controller performs all data transfers in this example. The Host uses an interrupt
service routine (ISR) to transfer data.
Starting Playback
1. CT8022 is in IDLE or RECORD state.
2. Host checks for CONTROL READY state in Hardware Status Register.
3. Host selects TrueSpeech 5.3 playback by writing the Select TrueSpeech Playback Rate command = 5232H to
the Software Control Register.
4. CT8022 responds via the Software Status Register.
5. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register. This clears the STATUS READY bit.
6. Host selects Poll Sync Mode for playback using the command 5202H.
7. CT8022 responds via the Software Status Register.
8. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register. This clears the STATUS READY bit.
9. Host selects Playback by issuing the PLAYBACK C1 command = 2C03H or 2C01H via the Software Control
Register. This also informs the CT8022 that data transfers will occur via the Host Transmit Data Buffer Access
Port (TFR Mode = [binary] 11 or 01).
10. CT8022 responds via the Software Status Register after a delay of up to 2 speech frame periods.
11. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register S1 = 2C03H or 2C01H. This clears the STATUS READY bit.
12. Host writes PLAYBACK C2 command = 2000H to the Software Control Register.
13. CT8022 responds via the Software Status Register.
14. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register S2 = 2000H. This clears the STATUS READY bit.
15. Host writes PLAYBACK C3 command = 200AH to the Software Control Register. This command includes the
requested number of words per frame to transfer. In this case (TrueSpeech 5.3) this is 10 = 0AH.
16. CT8022 responds via the Software Status Register.
17. Host waits for STATUS READY indication in the Hardware Status Register, then reads the CT8022 response
from the Software Status Register S3 = 200AH. This clears the STATUS READY bit.
18. Host sets up an ISR to service interrupts from the CT8022.
19. Host programs the Hardware Control Register to generate an interrupt from the CT8022 on the TX Ready
condition by writing 0402H ( Master Enable set, TX Ready IE set).