English
Language : 

S1X60000 Datasheet, PDF (14/358 Pages) Epson Company – EMBEDDED ARRAY
Chapter 1 Overview
Table 1-3 Recommended Operating Conditions (for a Single Power Supply at VDD = 2.5 V)
(VSS = 0 [V])
Parameter
Symbol Min.
Typ.
Max.
Unit
Power Supply Voltage
Input Voltage
Ambient Temperature
Normal Input Rising Time *4
Normal Input Falling Time *4
Schmitt Input Rising Time *4
Schmitt Input Falling Time *4
VDD
2.30
2.50
2.70
V
VI
-0.3
—
VDD + 0.3*1
V
0
25
70*2
Ta
-40
25
85*3
°C
tri
—
—
50
ns
tfa
—
—
50
ns
tri
—
—
5
ms
tfa
—
—
5
ms
Notes
*1: Possible to use up to 3.9 V of N channel open drain bi-directional buffers, input buffers, and
Fail-Safe cells.
*2: The ambient temperature range is recommended for Tj = 0 to +85 [°C].
*3: The ambient temperature range is recommended for Tj = -40 to +125 [°C].
*4: This is the finite time during which power supply voltage changes from 10% to 90% or vice versa.
Table 1-4 Recommended Operating Conditions (for a Single Power Supply at VDD = 2.0 V)
(VSS = 0 [V])
Parameter
Symbol Min.
Typ.
Max.
Unit
Power Supply Voltage
Input Voltage
Ambient Temperature
Normal Input Rising Time *4
Normal Input Falling Time *4
Schmitt Input Rising Time *4
Schmitt Input Falling Time *4
VDD
1.80
2.00
2.20
V
VI
-0.3
—
VDD + 0.3*1
V
0
25
70*2
Ta
-40
25
85*3
°C
tri
—
—
100
ns
tfa
—
—
100
ns
tri
—
—
10
ms
tfa
—
—
10
ms
Notes *1: Possible to use up to 3.9 V of N channel open drain bi-directional buffers, input buffers, and
Fail-Safe cells.
*2: The ambient temperature range is recommended for Tj = 0 to +85 [°C].
*3: The ambient temperature range is recommended for Tj = -40 to +125 [°C].
*4: This is the finite time during which power supply voltage changes from 10% to 90% or vice versa.
EMBEDDED ARRAY S1X60000 SERIES
EPSON
5