English
Language : 

DA9063_17 Datasheet, PDF (25/219 Pages) Dialog Semiconductor – System PMIC for Mobile Application Processors
DA9063
System PMIC for Mobile Application Processors
Table 12: 4-Wire Control Bus, TJ = -40 ºC to +125 ºC
Parameter
Symbol Label in Plot
Min
Typ
Bus line capacitive load
Cycle time
tC
1
70
Enable lead time
tCSS
2, from nCS active to first SK
20
edge
Enable lag time
tSCS
3, from last SK edge to nCS idle
20
Clock low time
tCL
4
0.4 * tC
Clock high time
tCH
5
0.4 * tC
Data-in setup time
tSIS
6
5
Data-in hold time
tSIH
7
5
Data-out valid time
tSOV
8
Data-out hold time
tSOH
9
6
CS inactive time
tWCS
11
20
Max Unit
100 pF
ns
ns
ns
ns
ns
ns
ns
22
ns
ns
ns
Datasheet
CFR0011-120-00
DA9063_2v1
25 of 219
23-Mar-2017
© 2017 Dialog Semiconductor