English
Language : 

DDC112 Datasheet, PDF (20/24 Pages) Burr-Brown (TI) – Dual Current Input 20-Bit ANALOG-TO-DIGITAL CONVERTER
CLK
DVALID
DXMIT
DCLK(1)
DIN
t18
t14
t20
t22
t24
DOUT
t21
Output Disabled
t22A, t22B
Input A
Bit 1
MSB
Output Enabled
Input E
Bit 20
LSB
Input F
Bit 1
MSB
NOTE: (1) Disable DCLK (preferably LOW) when DXMIT is HIGH.
t26
t25
Input F
Bit 20
LSB
t23
Output Disabled
FIGURE 23. Timing Diagram When Using the DIN Function of the DDC112.
CLK = 10MHz
SYMBOL
DESCRIPTION
MIN
TYP
MAX
t24
Set-Up Time From DIN to Rising Edge of DCLK
10
t25
Hold Time For DIN After Rising Edge of DCLK
10
t26
Hold Time for DXMIT HIGH Before Falling
2
Edge of DVALID
TABLE X. Timing for the DDC112 Data Retrieval Using DIN.
CLK = 15MHz
MIN
TYP
MAX
5
10
1.33
UNITS
ns
ns
µs
RETRIEVAL BEFORE CONV TOGGLES
(CONTINUOUS MODE)
This is the most straightforward method. Data retrieval
begins soon after DVALID goes LO and finishes before
CONV toggles, see Figure 24. For best performance, data
retrieval must stop t28 before CONV toggles. This method is
the most appropriate for longer integration times. The maxi-
mum time available for readback is TINT – t27 – t28.
For DCLK and CLK = 10MHz, the maximum number of
DDC112s that can be daisy-chained together is:
TINT – 431.2µs
40 τ DCLK
Where τDCLK is the period of the data clock. For example, if
TINT = 100µs and DCLK = 10MHz, the maximum number
of DDC112s is:
RETRIEVAL AFTER CONV TOGGLES
(CONTINUOUS MODE)
For shorter integration times, more time is available if data
retrieval begins after CONV toggles and ends before the
new data is ready. Data retrieval must wait t29 after CONV
toggles before beginning. Figure 25 shows an example of
this. The maximum time available for retrieval is t27 – t29 –
t26 (421.2µs – 10µs –2µs for CLK = 10MHz), regardless of
TINT. The maximum number of DDC112s that can be
daisy-chained together is:
409.2µs
40 τ DCLK
For DCLK = 10MHz, the maximum number of DDC112s is
102.
1000µs – 431.2µs = 142.2 → 142 DDC112s
(40)(100ns)
®
DDC112