Looking at the state diagram, one can see that the CONV
pattern needed to generate a given state progression is not
unique. Upon entering states 1 or 8, the DDC112 remains in
those states until mbsy goes LOW, independent of CONV.
As long as the m/r/az cycle is underway, the state machine
ignores CONV (see Figure 9). The top two signals are
different CONV patterns that produce the same state.
This feature can be a little confusing at first, but it does
allow flexibility in generating ncont mode CONV patterns.
For example, the DDC112 Evaluation Fixture operates in
the ncont mode by generating a square wave with pulse
width < t6. Figure 17 illustrates operation in the ncont mode
using a 50% duty cycle CONV signal with TINT = 1620
CLK periods. Care must be exercised when using a square
wave to generate CONV. There are certain integration
times that must be avoided since they produce very short
intervals for state 2 (or state 7 if CONV is inverted). As seen
in the state diagram, the state progresses from 2 to 3 as soon
as CONV is HIGH. The state machine does not insure that
the duration of state 2 is long enough to properly prepare the
next side for integration (t11). This must be done by the user
with proper timing of CONV. For example, if CONV is a
square wave with TINT = 3042 CLK periods, state 2 will
only be 18 CLK periods long, therefore, t11 will not be met.
CONV1
CONV2
mbsy
State
3
4
1
23
4
FIGURE 16. Equivalent CONV Signals in Non-Continuous Mode.
1
2
CONV
State
3
4
1
Integration
Status
mbsy
Int A Int B
DVALID
Side A
Data
2
3
4
Int A Int B
Side B
Data
FIGURE 17. Non-Continuous Mode Timing with a 50% Duty Cycle CONV Signal.
®