SPECIAL CONSIDERATIONS
NCONT MODE INTEGRATION TIME
The DDC112 uses a relatively fast clock. For CLK = 10MHz,
this allows TINT to be adjusted in steps of 100ns since CONV
should be synchronized to CLK. However, for the internal
measurement, reset and auto-zero operations, a slower clock
is more efficient. The DDC112 divides CLK by six and uses
this slower clock with a period of 600ns to run the m/r/az
cycle and data ready logic.
Because of the divider, it is possible for the integration time
to be a non-integer number of slow clock periods. For
example, if TINT = 5000 CLK periods (500µs for CLK = 10MHz),
there will be 833 1/3 slow clocks in an integration period.
This non-integer relationship between TINT and the slow
clock period causes the number of rising and falling slow
clock edges within an integration period to change from
integration to integration. The digital coupling of these
edges to the integrators will in turn change from integration
to integration which produces noise. The change in the clock
edges is not random, but will repeat every 3 integrations.
The coupling noise on the integrators appears as a tone with
a frequency equal to the rate at which the coupling repeats.
To avoid this problem in cont mode, the internal slow clock
is shut down after the m/r/az cycle is complete when it is no
longer needed. It starts up again just after the next integra-
tion begins. Since the slow clock is always off when CONV
toggles, the same number of slow clock edges fall within an
integration period regardless of its length. Therefore,
TINT ≥ 4794 CLK periods will not produce the coupling
problem described above.
For the ncont mode however, the slow clock must always be
left running. The m/r/az cycle is not completed before an
integration ends. It is then possible to have digital coupling
to the integrators. The digital coupling noise depends heavily
on the layout of the printed circuit board used for the
DDC112. For solid grounds and power supplies with good
bypassing, it is possible to greatly reduce the coupling.
However, for guaranteeing the best performance in the ncont
mode, the integration time should be chosen to be an integer
multiple of 1/(2fSLOWCLOCK). For CLK = 10MHz, the inte-
gration time should be an integer multiple of 300ns—
TINT = 100µs is not. A better choice would be TINT = 99µs.
DATA READY
The DVALID signal which indicates that data is ready is
generated using the internal slow clock. The phase relation-
ship between this clock and CLK is set when power is first
applied and is random. Since CONV is synchronized with
CLK, it will have a random phase relationship with respect
to the slow clock. When TINT > t6, the slow clock will
temporarily shut down as described above. This shutdown
process synchronizes the internal clock with CONV so that
the time between when CONV toggles to when DVALID
goes LOW (t7 and t8) is fixed.
For TINT ≤ t6, the internal slow clock, is not allowed to shut
down and the synchronization never occurs. Therefore, the
time between CONV toggling and DVALID indicating data
is ready has uncertainty due to the random phase relation-
ship between CONV and the slow clock. This variation is
±1/(2fSLOWCLOCK) or ±3/fCLK. The timing to the second
DVALID in the ncont mode will not have a variation since
it is triggered off the first data ready (t9) and both are
derived from the slow clock.
Polling DVALID to determine when data is ready eliminates
any concern about the variation in timing since the readback
is automatically adjusted as needed. If the data readback is
triggered off the toggling of CONV directly (instead of
polling), then waiting the maximum value of t7 or t8 insures
that data will always be ready before readback occurs.
Data Retrieval
In the continuous and non-continuous modes of operation,
the data from the last conversion is available for retrieval
with the falling edge of DVALID (see Figure 22). The
falling edge of DXMIT in combination with the data clock
(DCLK) will initiate the serial transmission of the data from
the DDC112. Typically, data is retrieved from the DDC112
as soon as DVALID falls and completed before the next
CONV transition from HIGH to LOW or LOW to HIGH
occurs. If this is not the case, care should be taken to stop
activity on DCLK and consequently DOUT by at least 10µs
around a CONV transition. If this caution is ignored it is
possible that the integration that is being initiated by CONV
will have additional noise introduced.
The serial output data at DOUT is transmitted in Straight
Binary Code per Table VIII. An output offset has been built
into the DDC112 to allow for the measurement of input
signals near and below zero. Board leakage up to ≈ –0.4%
of the positive full scale can be tolerated before the digital
output clips to all zeroes.
CODE
1111 1111 1111 1111 1111
1111 1111 1111 1111 1110
0000 0001 0000 0000 0001
0000 0001 0000 0000 0000
0000 0000 0000 0000 0000
INPUT SIGNAL
FS
FS – 1LSB
+1LSB
Zero
–0.4% FS
TABLE VIII. Straight Binary Code Table.
Cascading Multiple Converters
Multiple DDC112 units can be connected in serial or parallel
configurations, as illustrated in Figures 20 and 21.
DOUT can be used with DIN to “daisy chain” several
DDC112 devices together to minimize wiring. In this mode
of operation, the serial data output is shifted through mul-
tiple DDC112s, as illustrated in Figure 20.
RPULLUP prevents DIN from floating when DXMIT is HIGH.
Care should be taken to keep the capacitive load on DOUT
as low as possible when running CLK=15MHz.
®
DDC112