English
Language : 

U2739M-B Datasheet, PDF (61/69 Pages) ATMEL Corporation – DAB One-Chip Channel- and Source Decoder
U2739M-B
8.4.5 Read TII Data
Command Overview:
D Get TII data
Address Mode
7
6
5
4
3
2
1
0
0
1
1
0
1
1
1
1
DAB
U2739M-B
Write Command
Command
sequence:
$6F
Data Mode
7
6
5
4
3
2
1
0
0
1
1
1
0
0
TIINUM
$7X
Address Mode
7
6
5
4
3
2
1
0
0
1
1
0
1
1
0
1
DAB
U2739M-B
Write Command
$6D
Data Mode
7
6
5
4
3
2
1
0
TII0
$XX
...
TII31
$XX
Command Parameters:
Parameter
TIINUM
Meaning
TII block number n
TIIm
TII byte m
Description
The maximum TII capacity is 128 bytes.
The access is splitted into 4 blocks (numbered 0..3) of 32 bytes.
The blocks are time aligned, that means block 0 is the first filled block.
Byte 0 is the first byte of block n, byte 31 the last one. It is followed by
the first one of block n+1.
Rev. A1, 22-May-01
61 (69)