English
Language : 

U2739M-B Datasheet, PDF (38/69 Pages) ATMEL Corporation – DAB One-Chip Channel- and Source Decoder
U2739M-B
8.1.6 Set Current SBCHID Long Form
Command Settings Overview:
D Set current sub–channel parameters (long form)
Address Mode
7
6
5
4
3
2
1
0
0
1
1
0
1
1
1
0
DAB
U2739M-B
Write Command
Command
sequence:
$6E
Data Mode
7
6
5
4
3
2
1
0
0
0
0
1
0
1
0
0
$14
Address Mode
7
6
5
4
3
2
1
0
0
1
1
0
1
1
0
0
DAB
U2739M-B
Write Command
$6C
Data Mode
7
6
5
4
3
2
1
0
ON SCEFC
SBCHID
$XX
SCU(9..2)
$XX
SCU(1..0)
EP
EPPAR
CU(9..8)
$XX
CU(7..0)
$XX
38 (69)
Rev. A1, 22-May-01