Chapter 1: DC and Switching Characteristics for Stratix IV Devices
Switching Characteristics
1–34
Table 1–25 through Table 1–28 lists the typical differential VOD termination settings for
Stratix IV GX and GT devices.
Table 1–25. Typical VOD Setting, TX Term = 85 
Symbol
VOD Setting (mV)
0
1
2
3
4
5
VOD differential
170 ± 340 ± 510 ± 595 ± 680 ± 765 ±
peak-to-peak Typical (mV) 20% 20% 20% 20% 20% 20%
6
7
850 ± 1020 ±
20% 20%
Table 1–26. Typical VOD Setting, TX Term = 100 
Symbol
VOD Setting (mV)
0
1
2
3
4
5
6
7
VOD differential
200 ± 400 ± 600 ± 700 ± 800 ± 900 ± 1000 1200
peak-to-peak Typical (mV) 20% 20% 20% 20% 20% 20% ± 20% ± 20%
Table 1–27. Typical VOD Setting, TX Term = 120 
Symbol
VOD Setting (mV)
0
1
2
3
4
VOD differential
240 ± 480 ± 720 ± 840 ± 960 ±
peak-to-peak Typical (mV) 20% 20% 20% 20% 20%
5
1080 ±
20%
6
1200 ±
20%
Table 1–28. Typical VOD Setting, TX Term = 150 
Symbol
VOD differential
peak-to-peak Typical (mV)
0
300 ±
20%
1
600 ±
20%
VOD Setting (mV)
2
3
900 ±
20%
1050 ±
20%
4
1200 ±
20%
5
1350 ±
20%
Table 1–29 lists typical transmitter pre-emphasis levels in dB for the first post tap
under the following conditions (low-frequency data pattern [five 1s and five 0s] at
6.25 Gbps). The levels listed in Table 1–29 are a representation of possible
pre-emphasis levels under the specified conditions only and that the pre-emphasis
levels may change with data pattern and data rate.
f To predict the pre-emphasis level for your specific data rate and pattern, run
simulations using the Stratix IV HSSI HSPICE models.
Table 1–29. Transmitter Pre-Emphasis Levels for Stratix IV Devices (Part 1 of 2)
Pre-Emphasis 1st
VOD Setting
Post-Tap Setting
0
1
2
3
4
5
6
7
0
0
0
0
0
0
0
0
0
1
N/A
0.7
0
0
0
0
0
0
2
N/A
1
0.3
0
0
0
0
0
3
N/A
1.5
0.6
0
0
0
0
0
January 2014 Altera Corporation
Stratix IV Device Handbook
Volume 4: Device Datasheet and Addendum