AKD4683 Datasheet, PDF (36/74 Pages) Asahi Kasei Microsystems – AK4683 Evaluation Board Rev.1 | |||
|
◁ |
ASAHI KASEI
Measure Result
1) ADC part
[Measurement condition]
⢠Measurement unit : Audio Precision System two Cascade (AP2)
⢠MCLK
: 256fs (fs=48kHz), 256fs (fs=96kHz)
⢠BICK
: 64fs
⢠fs
: 48kHz, 96kHz
⢠BW
: 20Hzâ¼20kHz (fs=48kHz), 20Hzâ¼40kHz (fs=96kHz)
⢠Bit
: 24bit
⢠Power Supply : AVDD=PVDD=DVDD=5V, TVDD=3.3V
⢠Interface
: Internal DIT (fs=48kHz, 96kHz)
⢠Temperature : Room Temp
fs=48kHz
Parameter
S/(N+D)
DR
DR
S/N
S/N
Input signal
1kHz, -0.5dB
1kHz, -60dB
1kHz, -60dB
No signal
No signal
Measurement filter
20kLPF
20kLPF
20kLPF, A-weighted
20kLPF
20kLPF, A-weighted
Results
93.1 dB
97.1 dB
100.6 dB
98.2 dB
101.1 dB
fs=96kHz
Parameter
S/(N+D)
DR
DR
S/N
S/N
Input signal
1kHz, -0.5dB
1kHz, -60dB
1kHz, -60dB
No signal
No signal
Measurement filter
fs/2
fs/2
20kLPF, A-weighted
fs/2
20kLPF, A-weighted
Results
92.0 dB
96.3 dB
102.7 dB
96.3 dB
102.9 dB
[AKD4683-A]
<KM077504>
- 36 -
2005/08
|
▷ |