U1AFS250-FG256 Datasheet, PDF (2/27 Pages) Actel Corporation – 3 - DC and Power Characteristics | |||
|
◁ |
DC and Power Characteristics
Table 3-1 ⢠Absolute Maximum Ratings (continued)
Symbol
Parameter
Commercial
Industrial
Units
Analog input (direct input to ADC)
â0.4 to 3.75
â0.4 to 3.75
V
Digital input
â0.4 to 12.6
â0.4 to 12.4
V
AG
Unpowered, ADC reset asserted or â11.0 to 12.6
unconfigured
â11.0 to 12.4
V
Low Current Mode (1 µA, 3 µA, 10 µA, 30 µA)
â0.4 to 12.6
â0.4 to 12.4
V
Low Current Mode (â1 µA, â3 µA, â10 µA, â30
µA)
High Current Mode3
â11.0 to 0.4
â11.0 to 12.6
â11.0 to 0.4
V
â11.0 to 12.4
V
AT
Unpowered, ADC reset asserted or
â0.4 to 16.5
unconfigured
â0.4 to 16.0
V
Analog input (+16 V, 4 V prescaler range)
â0.4 to 16.5
â0.4 to 16.0
V
Analog input (direct input to ADC)
â0.4 to 3.75
â0.4 to 3.75
V
Digital input
â0.4 to 16.5
â0.4 to 16.0
V
TSTG3
Tj3
Storage temperature
Junction temperature
â65 to +150
°C
+125
°C
Notes:
1. The device should be operated within the limits specified by the datasheet. During transitions, the input
signal may undershoot or overshoot according to the limits shown in Table 3-4 on page 3-4.
2. Analog data not valid beyond 3.65 V.
3. For flash programming and retention maximum limits, refer to Table 3-5 on page 3-5. For recommended
operating limits refer to Table 3-2 on page 3-3.
3-2