U1AFS250-FG256 Datasheet, PDF (10/27 Pages) Actel Corporation – 3 - DC and Power Characteristics
DC and Power Characteristics
Calculating Power Dissipation
Quiescent Supply Current
Table 3-8 • Quiescent Supply Current Characteristics (IDDQ)1
Parameter
Conditions and Modes
U1AFS250
U1AFS600
U1AFS1500
IDC1
Maximum in operating mode (85°C) 1
30 mA
45 mA
TBD
Maximum in operating mode (70°C) 1
20 mA
30 mA
TBD
Typical in operating mode (25°C) 1
3 mA
5 mA
TBD
IDC2
Typical in standby mode (25°C) 2,4
IDC3
Typical in sleep mode (25°C) 3,4
200 µA
200 µA
TBD
10 µA
10 µA
TBD
Notes:
1. IDC1 includes VCC, VPUMP, and VCCI, currents. Values do not include I/O static contribution, which is shown in
Table 3-9 on page 3-11 and Table 3-10 on page 3-13.
2. IDC2 represents the current from the VCC33A and VCCI supplies when the RTC (and the 32 kHz crystal
oscillator) is ON, the FPGA is OFF, and the voltage regulator is OFF.
3. IDC3 represents the current from the VCC33A and VCCI supplies when the RTC (and the crystal oscillator), the
FPGA, and the voltage regulator are OFF.
4. VCCI supply is ON, since the east and west I/O banks are not cold-sparable. Values do not include I/O static
contribution, which is shown in Table 3-9 on page 3-11 and Table 3-10 on page 3-13.
3-10
Preliminary v0.4