EX128-TQG100A Datasheet, PDF (16/44 Pages) Actel Corporation – eX Automotive Family FPGAs | |||
|
◁ |
eX Automotive Family FPGAs
Operating Conditions
Table 1-8 ⢠Absolute Maximum Ratings*
Symbol
Parameter
Limits
Units
VCCI
DC Supply Voltage for I/Os
â0.3 to +4.0
V
VCCA
DC Supply Voltage for Array
â0.3 to +3.0
V
VI
Input Voltage
â0.5 to VCCI + 0.5
V
VO
Output Voltage
â0.5 to +VCCI
V
TSTG
Storage Temperature
â65 to +150
°C
Tj
Maximum Junction Temperature
â65 to +150
°C
Note: *Stresses beyond those listed under âAbsolute Maximum Ratingsâ may cause permanent damage to the device. Exposure to
temperatures between absolute maximum and recommended operating conditions for extended periods may affect device
reliability. Devices should not be operated outside the Recommended Operating Conditions.
Table 1-9 ⢠Recommended Operating Conditions
Parameter
Automotive
Units
Temperature Range (Tj)
â40 to +125
°C
2.5 V Power Supply
Range (VCCA, VCCI)
2.3 to 2.7
V
3.3 V Power Supply
Range (VCCI)
3.0 to 3.6
V
Note: Automotive grade parts (A grade) devices are tested at room temperature to specifications that have been guard banded based on
characterization across the recommended operating conditions. A-grade parts are not tested at extended temperatures. If testing
to ensure guaranteed operation at extended temperatures is required, please contact your local Actel Sales office to discuss testing
options available.
Table 1-10 ⢠Typical Automotive-Grade eX Standby Current at 25°C
Product
eX64
VCCA= 2.5 V
VCCI = 2.5 V
397 µA
eX128
696 µA
eX256
698 µA
VCCA = 2.5 V
VCCI = 3.3 V
497 µA
795 µA
796 µA
1-12
v3.2
|
▷ |