English
Language : 

Z02215 Datasheet, PDF (33/74 Pages) Zilog, Inc. – Single Chip Modem with Integrated Controller, Data Pump, and Analog Front End
Z02215
Single Chip Modem with Integrated Controller, Data Pump, and AFE
27
Table 3. AT Command Set (Continued)
Command
Function and Description
O
Return to The O command returns the modem to the ON-LINE mode. It frequently follows
ON-LINE the escape character sequence (+++) to resume communication with the
Mode
remote modem. If handshaking is started, the modem uses ORIGINATE or
ANSWER mode handshaking.
O0
This option returns the modem to the ON-LINE state from
the COMMAND state during a telephone line connection.
The modem starts handshaking if there is no telephone line
connection but the modem was off-hook.
O1
This option returns the modem to the ON-LINE state and
retrains its data pump during a telephone line connection.
The modem starts handshaking if no telephone line
connection exists and the modem is off-hook.
P
Pulse
Selects the PULSE method of dialing. Pulse is the default dialing method in
Dialing
North America.
&P
Pulse Dial The &P command sets the cadence of the pulse dial. The country configuration
Make/Break may disable this command, forcing particular pulse dialing parameters. When
Ratios
country restrictions are in effect and this command is issued, the modem
returns an ERROR result.
&P0
39%/61% make/break ratio and 10 pulses per second when
pulse dialing. This value is the default value.
&P1
33%/67% make/break ratio and 10 pulses per second when
pulse dialing.
&P2
39%/61% make/break ratio and 20 pulses per second when
pulse dialing.
&P3
33%/67% make/break ratio and 20 pulses per second when
pulse dialing.
Q
Result Code This command enables or disables display of result codes.
Display
Q0
Options
For this option, result codes are displayed. This value is the
default value for North America.
Q1
Result codes are not displayed.
PS001907-0904