English
Language : 

X5001 Datasheet, PDF (14/19 Pages) Xicor Inc. – CPU Supervisor
X5001
VTRIP Programming Parameters
Parameter
Description
tVPS
VTRIP Program Enable Voltage Setup time
tVPH
VTRIP Program Enable Voltage Hold time
tPCS
VTRIP Programming CS inactive time
tTSU
VTRIP Setup time
tTHD
VTRIP Hold (stable) time
tWC
VTRIP Write Cycle Time
tVPO
VTRIP Program Enable Voltage Off time
(Between successive adjustments)
tRP
VTRIP Program Recovery Period
(Between successive adjustments)
VP
Programming Voltage
VTRAN
VTRIP Programmed Voltage Range
Vta1
Initial VTRIP Program Voltage accuracy
(Vcc applied - VTRIP) (Programmed at 25oC.)
Vta2
Subsequent VTRIP Program Voltage accuracy
[(Vcc applied - Vta1) - VTRIP. Programmed at 25oC.)
Vtr
VTRIP Program Voltage repeatability
(Successive program operations. Programmed at 25oC.)
Vtv
VTRIP Program variation after programming (0-75oC).
(Programmed at 25oC.)
VTRIP Programming parameters are periodically sampled and are not 100% Tested.
Min
Max
Units
1
µs
1
µs
1
µs
1
µs
10
ms
10
ms
0
us
10
ms
15
18
V
1.7
5.0
V
-0.1
+0.4
V
-25
+25
mV
-25
+25
mV
-25
+25
mV
14