W741E20X Datasheet, PDF (68/84 Pages) Winbond – 4-BIT FLASH MICROCONTROLLER | |||
|
◁ |
Preliminary W741E20X
Instruction Set Table 2, continued
MOVA R, WR
Move WR content to ACC & R
Machine Code:
Machine Cycle:
Operation:
Description:
Flag Affected:
MOVA WR, R
0 1 1 1 1 W3 W2 W1 W0 R6 R5 R4 R3 R2 R1 R0
1
ACC, R â (WR)
The contents of the WR are loaded to the ACC and the data memory
location addressed by R6 to R0.
ZF
Move R content to ACC & WR
Machine Code:
Machine Cycle:
Operation:
Description:
Flag Affected:
MOV TABL, R
0 1 1 0 1 W3 W2 W1 W0 R6 R5 R4 R3 R2 R1 R0
1
ACC, WR â (R)
The contents of the data memory location addressed by R6 to R0 are
loaded to the WR and the ACC.
ZF
Move R content to TABL
Machine Code:
Machine Cycle:
Operation:
Description:
MOV TABH, R
10011000
0 R6 R5 R4 R3 R2 R1 R0
1
TABL â (R)
The content of the data memory location addressed by R6 to R0 are loaded
into the TABL.
Move R content to TABH
Machine code:
Machine Cycle:
Operation:
Description:
10011000
1 R6 R5 R4 R3 R2 R1 R0
1
TABH â (R)
The content of the data memory location addressed by R6 to R0 are loaded
into the TABH.
- 68 -
|
▷ |