English
Language : 

W987D6HBGX6E-TR Datasheet, PDF (57/68 Pages) Winbond – 128Mb Mobile LPSDR
W987D6HB / W987D2HB
10.16 Deep Power Down Mode Exit
128Mb Mobile LPSDR
CLK
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
CS
RAS
tRP
tRSC
tRSC
CAS
WE
A10
Address
OP-Code OP-Code
DQM
CKE
tCKS
DQ
200μs
tRCF
DSL All Banks Precharge
Extended Mode
Register Set Auto Refresh
Auto Refresh
Auto Refresh Arbitrary Cycle
Deep Power Down Exit
Mode Register Set
Issue Auto Refresh cycle two or more
Note:
The device exits the Deep Power Down Mode asynchronously at the rising edge of the CKE signal.
After CKE goes high, the Device Deselect or No-operation command must be register at the immediately
following CLK rising edge, and CKE must remain high at least for tCKS delay immediately after exiting the
Deep Power Down Mode.
- 57 -
Publication Release Date: Jun. 09, 2011
Revision A01-002