Mode 1
Mode 1 is similar to Mode 0 except that the counting register forms a 16 bit counter, rather than a 13
bit counter. This means that all the bits of THx and TLx are used. Roll-over occurs when the timer
moves from a count of FFFFh to 0000h. The timer overflow flag TFx of the relevant timer is set and if
enabled an interrupt will occur. The selection of the time-base in the timer mode is similar to that in
Mode 0. The gate function operates similarly to that in Mode 0.
Mode 2
In Mode 2, the timer/counter is in the Auto Reload Mode. In this mode, TLx acts as a 8 bit count
register, while THx holds the reload value. When the TLx register overflows from FFh to 00h, the TFx
bit in TCON is set and TLx is reloaded with the contents of THx, and the counting process continues
from here. The reload operation leaves the contents of the THx register unchanged. Counting is
enabled by the TRx bit and proper setting of GATE and INTx pins. As in the other two modes 0 and 1
mode 2 allows counting of either clock cycles (clock/12 or clock/4) or pulses on pin Tn.
osc
T0 = P3.4
(T1 = P3.5)
T0M = CKCON.3
(T1M = CKCON.4)
1/4
1
C/T = TMOD.2
(C/T = TMOD.6)
0
0
1/12
1
TR0 = TCON.4
(TR1 = TCON.6)
GATE = TMOD.3
(GATE = TMOD.7)
INT0 = P3.2
(INT1 = P3.3)
Timer 1 functions are shown in brackets
TL0
(TL1)
0
7
TFx
TF0
(TF1)
Interrupt
0
7
TH0
(TH1)
Timer/Counter Mode 2
Mode 3
Mode 3 has different operating methods for the two timer/counters. For timer/counter 1, mode 3 simply
freezes the counter. Timer/Counter 0, however, configures TL0 and TH0 as two separate 8 bit count
registers in this mode. The logic for this mode is shown in the figure. TL0 uses the Timer/Counter 0
control bits C/T , GATE, TR0, INT0 and TF0. The TL0 can be used to count clock cycles (clock/12 or
clock/4) or 1-to-0 transitions on pin T0 as determined by C/T (TMOD.2). TH0 is forced as a clock
cycle counter (clock/12 or clock/4) and takes over the use of TR1 and TF1 from Timer/Counter 1.
Mode 3 is used in cases where an extra 8 bit timer is needed. With Timer 0 in Mode 3, Timer 1 can
still be used in Modes 0, 1 and 2., but its flexibility is somewhat limited. While its basic functionality is
maintained, it no longer has control over its overflow flag TF1 and the enable bit TR1. Timer 1 can still
be used as a timer/counter and retains the use of GATE and INT1 pin. In this condition it can be
turned on and off by switching it out of and into its own Mode 3. It can also be used as a baud rate
generator for the serial port.