English
Language : 

TL16PNP200 Datasheet, PDF (9/23 Pages) Texas Instruments – STANDALONE PLUG-AND-PLAY (PnP) CONTROLLER
TL16PNP200
STANDALONE PLUGĆANDĆPLAY (PnP) CONTROLLER
SLLS229A − NOVEMBER 1995 − REVISED APRIL 1996
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC (See Note 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 6 V
Input voltage range, VI: Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC +0.5 V
Fail safe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 6.5 V
Output voltage range, VO: Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC +0.5 V
Fail safe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 6.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) (see Note 9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) (see Note 8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 8. This applies for external output and bidirectional buffers. VO > VCC does not apply to fail-safe terminals..
9. This applies for external input and bidirectional buffers. VI > VCC does not apply to fail-safe terminals.
recommended operating conditions
Supply voltage, VCC
High-level input voltage, VIH
Low-level input voltage, VIL
Operating free-air temperature, TA
MIN NOM MAX UNIT
4.75
5 5.25 V
2
VCC V
0
0.8 V
0
70 °C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
9