English
Language : 

MSP430F4796IPZ Datasheet, PDF (9/89 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F47x
MIXED SIGNAL MICROCONTROLLER
SLAS629A -- MARCH 2009 -- REVISED APRIL 2009
Terminal Functions (continued)
TERMINAL
NAME
NO.
I/O
80 113
PIN PIN
DESCRIPTION
S17
24
L4
O LCD segment output 17
S18
25
M4
O LCD segment output 18
S19
26
J4
O LCD segment output 19
S22
29
L6
O LCD segment output 22
S23
30
M6
O LCD segment output 23
S24
31
L7
O LCD segment output 24
S25
32
M7
O LCD segment output 25
GND
7
E2
Ground. It is used to shield the oscillator. See Note 1.
XIN
8
E1
I Input port for crystal oscillator XT1. Standard or watch crystals can be connected.
XOUT
9
F1
O Output port for crystal oscillator XT1. Standard or watch crystals can be connected.
GND
10
F2
Ground. It is used to shield the oscillator. See Note 1.
VREF
RST/NMI
60 A12 O Input for an external reference voltage/internal reference voltage output
74
B5
I Reset input, nonmaskable interrupt input port, or bootstrap loader start (in flash devices).
TCK
73
A5
Test clock (JTAG). TCK is the clock input port for device programming test and bootstrap loader
I
start.
TDI/TCLK
71
A6
I Test data input or test clock input. The device protection fuse is connected to TDI/TCLK.
TDO/TDI
70
B7
I/O Test data output port. TDO/TDI data output or programming data input terminal.
TMS
72
B6
I Test mode select. TMS is used as an input port for device programming and test.
XT2OUT
68
A8
O Output terminal of crystal oscillator XT2
XT2IN
69
A7
I Input port for crystal oscillator XT2
Reserved
NA B11,
D6, D7,
D8, E4,
E5, E6,
E7, E8,
E9, F4,
F5, F8,
F9, G4,
G5,G8,
G9, H4,
H5, H6,
H7, H8,
H9, J5,
J6, J7,
J8, L11
BGA package unused balls. Connection to DVSS/AVSS recommended.
NOTE 1: It is recommended to connect GND externally to DVss.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
9