MSP430F47x
MIXED SIGNAL MICROCONTROLLER
SLAS629A -- MARCH 2009 -- REVISED APRIL 2009
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
Schmitt-trigger inputs -- Ports P1, P2, P3, P4, P5, and P6, RST/NMI, JTAG (TCK, TMS, TDI/TCLK, TDO/TDI)
PARAMETER
VIT+
Positive-going input threshold voltage
VCC
2.2 V
3V
MIN MAX UNIT
1.1 1.55
V
1.5 1.98
VIT--
Negative-going input threshold voltage
2.2 V
3V
0.4 0.9
V
0.9 1.3
Vhys
Input voltage hysteresis (VIT+ -- VIT--)
2.2 V
3V
0.3 1.1
V
0.5
1
inputs Px.y, TAx
PARAMETER
t(int)
External interrupt timing
TEST CONDITIONS
Port P1, P2: P1.x to P2.x, external trigger signal
for the interrupt flag (see Note 1)
VCC
2.2 V
3V
MIN MAX UNIT
62
ns
50
t(cap)
Timer_A capture timing
TA0, TA1, TA2
2.2 V
62
ns
3V
50
f(TAext)
Timer_A clock frequency externally
applied to pin
TACLK, INCLK: t(H) = t(L)
2.2 V
3V
8
MHz
10
f(TAint) Timer_A clock frequency
SMCLK or ACLK signal selected
2.2 V
3V
8
MHz
10
NOTES: 1. The external signal sets the interrupt flag every time the minimum t(int) parameters are met. It may be set even with trigger signals
shorter than t(int).
leakage current -- Ports P1, P2, P3, P4, P5, and P6 (see Note 1)
PARAMETER
TEST CONDITIONS
MIN MAX
Ilkg(Px.y)
Leakage current
Port Px V(Px.y) (see Note 2)
VCC = 2.2 V/3 V
±50
NOTES: 1. The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
2. The port pin must be selected as input.
UNIT
nA
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265