English
Language : 

MSP430F4796IPZ Datasheet, PDF (40/89 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F47x
MIXED SIGNAL MICROCONTROLLER
SLAS629A -- MARCH 2009 -- REVISED APRIL 2009
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
Comparator_A (see Note 1)
I(CC)
PARAMETER
TEST CONDITIONS
CAON = 1, CARSEL = 0, CAREF = 0
VCC
2.2 V
3V
MIN TYP MAX UNIT
25
40
µA
45
60
I(Refladder/RefDiode)
CAON = 1, CARSEL = 0,
CAREF = 1/2/3,
No load at P1.6/CA0 and P1.7/CA1
2.2 V
3V
30
50
µA
45
80
V(Ref025)
V(Ref050)
V(RefVT)
VIC
Voltage @ 0.25 VCC node
VCC
Voltage @ 0.5 VCC node
VCC
See Figure 15 and
Figure 16
Common-mode input
voltage range
PCA0 = 1, CARSEL = 1, CAREF = 1,
No load at P1.6/CA0 and P1.7/CA1
PCA0 = 1, CARSEL = 1, CAREF = 2,
No load at P1.6/CA0 and P1.7/CA1
PCA0 = 1, CARSEL = 1, CAREF = 3,
No load at P1.6/CA0 and P1.7/CA1,
TA = 85°C
CAON = 1
2.2 V / 3 V
2.2 V / 3 V
2.2 V
3V
2.2 V / 3 V
0.23 0.24 0.25
0.47 0.48
0.5
390 480
400 490
540
mV
550
0
VCC--1 V
Vp--VS
Offset voltage
See Note 2
2.2 V / 3 V --30
30 mV
Vhys
Input hysteresis
CAON = 1
2.2 V / 3 V
0 0.7
1.4 mV
t(response LH and HL), see Note 3
TA = 25°C,
Overdrive 10 mV, without filter: CAF = 0
TA = 25°C
Overdrive 10 mV, with filter: CAF = 1
2.2 V
3V
2.2 V
3V
80 165
70 120
1.4 1.9
0.9 1.5
300
ns
240
2.8
µs
2.2
NOTES: 1. The leakage current for the Comparator_A terminals is identical to Ilkg(Px.x) specification.
2. The input offset voltage can be cancelled by using the CAEX bit to invert the Comparator_A inputs on successive measurements.
The two successive measurements are then summed together.
3. The response time is measured at P1.6/CA0 with an input voltage step and the Comparator_A already enabled (CAON = 1). If CAON
is set at the same time, a settling time of up to 300 ns is added to the response time.
40