English
Language : 

MSP430F4796IPZ Datasheet, PDF (32/89 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F47x
MIXED SIGNAL MICROCONTROLLER
SLAS629A -- MARCH 2009 -- REVISED APRIL 2009
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted)
SVS (supply voltage supervisor/monitor)
PARAMETER
t(SVSR)
td(SVSon)
tsettle
V(SVSstart)
TEST CONDITIONS
dVCC/dt > 30 V/ms (see Figure 10)
dVCC/dt ≤ 30 V/ms
SVS ON, switch from VLD = 0 to VLD ≠ 0, VCC = 3 V
VLD ≠ 0‡
VLD ≠ 0, VCC/dt ≤ 3 V/s (see Figure 10)
Vhys(SVS_IT--)
VCC/dt ≤ 3 V/s (see Figure 10)
VCC/dt ≤ 3 V/s (see Figure 10),
External voltage applied on A7
MIN
5
20
VLD = 1
VLD = 2 to 14
70
V(SVS_IT--)
x 0.001
VLD = 15
4.4
TYP
1.55
120
MAX
150
2000
150
12
1.7
210
V(SVS_IT--)
x 0.016
UNIT
µs
µs
µs
µs
V
mV
20
mV
VLD = 1
VLD = 2
1.8
1.9
2.05
1.94
2.1
2.25
VLD = 3
VLD = 4
2.05
2.2
2.37
2.14
2.3
2.48
VLD = 5
VLD = 6
2.24
2.4
2.6
2.33
2.5
2.71
V(SVS_IT--)
VCC/dt ≤ 3 V/s (see Figure 10 and Figure 11)
VLD = 7
VLD = 8
VLD = 9
VLD = 10
2.46
2.65
2.86
2.58
2.8
3
V
2.69
2.9
3.13
2.83
3.05
3.29
VCC/dt ≤ 3 V/s (see Figure 10 and Figure 11),
External voltage applied on A7
VLD = 11
VLD = 12
VLD = 13
VLD = 14
VLD = 15
2.94
3.11
3.24
3.43
1.1
3.2
3.35
3.5
3.7†
1.2
3.42
3.61†
3.76†
3.99†
1.3
ICC(SVS)
(see Note 1)
VLD ≠ 0, VCC = 2.2 V/3 V
10
15
µA
† The recommended operating voltage range is limited to 3.6 V.
‡ tsettle is the settling time that the comparator o/p needs to have a stable level after VLD is switched VLD ≠ 0 to a different VLD value somewhere
between 2 and 15. The overdrive is assumed to be > 50 mV.
NOTE 1: The current consumption of the SVS module is not included in the ICC current consumption data.
32
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265