English
Language : 

MSP430F677X_16 Datasheet, PDF (79/162 Pages) Texas Instruments – Polyphase Metering SoCs
ECCN 5E002 TSPA - Technology / Software Publicly Available
MSP430F677x, MSP430F676x, MSP430F674x
www.ti.com
SLAS768D – SEPTEMBER 2012 – REVISED DECEMBER 2013
eUSCI (I2C Mode)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 17)
feUSCI
PARAMETER
eUSCI input clock frequency
TEST CONDITIONS
Internal: SMCLK, ACLK
External: UCLK
Duty cycle = 50% ± 10%
VCC
MIN TYP MAX UNIT
fSYSTEM MHz
fSCL
tHD,STA
tSU,STA
tHD,DAT
tSU,DAT
tSU,STO
SCL clock frequency
Hold time (repeated) START
Setup time for a repeated START
Data hold time
Data setup time
Setup time for STOP
fSCL = 100 kHz
fSCL > 100 kHz
fSCL = 100 kHz
fSCL > 100 kHz
fSCL = 100 kHz
fSCL > 100 kHz
fSCL = 100 kHz
fSCL > 100 kHz
UCGLITx = 0
2 V, 3 V
0
5.1
2 V, 3 V
1.5
5.1
2 V, 3 V
1.4
2 V, 3 V
0.4
5.0
2 V, 3 V
1.3
5.2
2 V, 3 V
1.7
75
400 kHz
µs
µs
µs
µs
µs
220 ns
tSP
Pulse duration of spikes suppressed by input UCGLITx = 1
filter
UCGLITx = 2
35
2 V, 3 V
30
120 ns
60 ns
UCGLITx = 3
20
35 ns
UCCLTOx = 1
30
ms
tTIMEOUT Clock low timeout
UCCLTOx = 2
UCCLTOx = 3
2 V, 3 V
33
ms
37
ms
SDA
tHD,STA
tSU,STA
tHD,STA
tBUF
tLOW
tHIGH
tSP
SCL
tHD,DAT
tSU,DAT
Figure 17. I2C Mode Timing
tSU,STO
Schmitt-Trigger Inputs – RTC Tamper Detect Pin
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
AUXVCC3 MIN TYP
VIT+ Positive-going input threshold voltage
1.8 V
0.80
3V
1.50
VIT– Negative-going input threshold voltage
1.8 V
0.45
3V
0.75
Vhys Input voltage hysteresis (VIT+ – VIT–)
1.8 V
0.3
3V
0.4
RPull Pullup or pulldown resistor
For pullup: VIN = VSS
For pulldown: VIN =
AUXVCC3
20
35
CI
Input capacitance
VIN = VSS or AUXVCC3
5
MAX
1.40
2.10
1.00
1.65
0.85
1.0
UNIT
V
V
V
50 kΩ
pF
Copyright © 2012–2013, Texas Instruments Incorporated
Submit Documentation Feedback
79