English
Language : 

DS99R103_14 Datasheet, PDF (6/30 Pages) Texas Instruments – 3-40MHz DC-Balanced 24-Bit LVDS Serializer and Deserializer
DS99R103, DS99R104
SNLS241D – MARCH 2007 – REVISED APRIL 2013
www.ti.com
Serializer Switching Characteristics (continued)
Over recommended operating supply and temperature ranges unless otherwise specified.
Parameter
Test Conditions
Min
tHZD
DOUT ± HIGH to TRI-STATE Delay RL = 100Ω,
tLZD
DOUT ± LOW to TRI-STATE Delay
CL = 10 pF to GND
(Figure 6)(2)
tZHD
DOUT ± TRI-STATE to HIGH Delay
tZLD
DOUT ± TRI-STATE to LOW Delay
tPLD
Serializer PLL Lock Time
RL = 100Ω, (Figure 7)
tSD
Serializer Delay
RL = 100Ω, (Figure 8)
VODSEL = L, TRFB = H
RL = 100Ω, (Figure 8)
VODSEL = L, TRFB = L
TxOUT_E_O TxOUT_Eye_Opening (respect to
ideal)
3–40 MHz
(Figure 9)(3)(4)
Typ
10
3.5T +
2.85
3.5T +
2.85
0.68
Max
15
15
200
200
3.5T +
10
3.5T +
10
Units
ns
ns
ns
ns
ms
ns
ns
UI
(5)
(2) When the Serializer output is at TRI-STATE, the Deserializer will lose PLL lock. Resynchronization MUST occur before data transfer.
(3) tJIT (@BER of 10e-9) specifies the allowable jitter on TCLK. tJIT not included in TxOUT_E_O parameter.
(4) TxOUT_E_O is affected by pre-emphasis value.
(5) UI – Unit Interval, equivalent to one ideal serialized data bit width. The UI scales with frequency.
Deserializer Switching Characteristics
Over recommended operating supply and temperature ranges unless otherwise specified.
Parameter
Test Conditions Pin/Freq.
Min
Typ
Max
tRCP
Receiver out Clock Period
tRCP = tTCP (1)
RCLK
25
T
333
tRDC
RCLK Duty Cycle
RCLK
45
50
55
tCLH
LVCMOS Low-to-High Transition Time CL = 8 pF
ROUT [23:0],
tCHL
LVCMOS High-to-Low Transition Time
(lumped load)
(Figure 11)
LOCK, RCLK
2.5
3.5
2.5
3.5
tROS
ROUT (7:0) Setup Data to RCLK
(Group 1)
tROH
ROUT (7:0) Hold Data to RCLK
(Group 1)
tROS
ROUT (15:8) Setup Data to RCLK
(Group 2)
tROH
ROUT (15:8) Hold Data to RCLK
(Group 2)
tROS
ROUT (23:16) Setup Data to RCLK
(Group 3)
tROH
ROUT (23:16) Hold Data to RCLK
(Group 3)
tHZR
HIGH to TRI-STATE Delay
tLZR
LOW to TRI-STATE Delay
tZHR
TRI-STATE to HIGH Delay
tZLR
TRI-STATE to LOW Delay
tDD
Deserializer Delay
tDRDL
Deserializer PLL Lock Time from
Powerdown
RxIN_TOL_L Receiver INput TOLerance Left
RxIN_TOL_R Receiver INput TOLerance Right
(Figure 15)
ROUT [7:0]
(Figure 15)
(Figure 15)
(Figure 13)
ROUT [15:8],
LOCK
ROUT
[23:16]
ROUT [23:0],
RCLK, LOCK
(Figure 12)
RCLK
(Figure 14)(2)(1) 3 MHz
(Figure 16)(3)(1)(4)
(Figure 16)(3)(1)(4)
40 MHz
3 MHz–40
MHz
3 MHz–40
MHz
(0.40)*
tRCP
(0.40)*
tRCP
(0.40)*
tRCP
(0.40)*
tRCP
(0.40)*
tRCP
(0.40)*
tRCP
(29/56)*tRCP
(27/56)*tRCP
0.5*tRCP
0.5*tRCP
(27/56)*tRCP
(29/56)*tRCP
3
3
3
3
[4+(3/56)]T
+5.9
5
5
10
10
10
10
[4+(3/56)]T
+18.5
50
50
0.25
0.25
Units
ns
%
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ms
ms
UI
UI
(1) Specification is ensured by characterization and is not tested in production.
(2) The Deserializer PLL lock time (tDRDL) may vary depending on input data patterns and the number of transitions within the pattern.
(3) RxIN_TOL is a measure of how much phase noise (jitter) the deserializer can tolerate in the incoming data stream before bit errors
occur. It is a measurement in reference with the ideal bit position, please see TI’s AN-1217 (Literature Number SNLA053) for detail.
(4) UI – Unit Interval, equivalent to one ideal serialized data bit width. The UI scales with frequency.
6
Submit Documentation Feedback
Copyright © 2007–2013, Texas Instruments Incorporated
Product Folder Links: DS99R103 DS99R104