English
Language : 

MSP432P401R_16 Datasheet, PDF (50/200 Pages) Texas Instruments – Mixed-Signal Microcontrollers
MSP432P401R, MSP432P401M
SLAS826E – MARCH 2015 – REVISED JULY 2016
www.ti.com
High-Frequency Crystal Oscillator, HFXT (continued)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
fOSC = 1 MHz,
HFXTBYPASS = 0, HFXTDRIVE = 0,
HFFREQ = 0, CL,eff = 16 pF,
Typical ESR and CSHUNT,
FCNTHF_EN = 0
VCC
MIN TYP MAX UNIT
4
fOSC = 4 MHz,
HFXTBYPASS = 0, HFXTDRIVE = 1,
HFFREQ = 0, CL,eff = 16 pF,
Typical ESR and CSHUNT,
FCNTHF_EN = 0
fOSC = 8 MHz,
HFXTBYPASS = 0, HFXTDRIVE = 1,
HFFREQ = 1, CL,eff = 16 pF,
Typical ESR and CSHUNT,
FCNTHF_EN = 0
1.8
ms
0.7
tSTART,HFXT
Start-up time(4)
fOSC = 16 MHz,
HFXTBYPASS = 0, HFXTDRIVE = 1,
HFFREQ = 2, CL,eff = 16 pF,
0.6
Typical ESR and CSHUNT,
FCNTHF_EN = 0
3.0 V
fOSC = 24 MHz,
HFXTBYPASS = 0, HFXTDRIVE = 1,
HFFREQ = 3, CL,eff = 16 pF,
450
Typical ESR and CSHUNT,
FCNTHF_EN = 0
fOSC = 32 MHz,
HFXTBYPASS = 0, HFXTDRIVE = 1,
HFFREQ = 4, CL,eff = 16 pF,
Typical ESR and CSHUNT,
FCNTHF_EN = 0
fOSC = 40 MHz,
HFXTBYPASS = 0, HFXTDRIVE = 1,
HFFREQ = 5, CL,eff = 16 pF,
Typical ESR and CSHUNT,
FCNTHF_EN = 0
300
µs
250
fOSC = 48 MHz,
HFXTBYPASS = 0, HFXTDRIVE = 1,
HFFREQ = 6, CL,eff = 16 pF,
250
Typical ESR and CSHUNT,
FCNTHF_EN = 0
CHFXIN
Integrated load capacitance at
HFXIN terminal(5) (6)
2
pF
CHFXOUT
fFault,HFXT
Integrated load capacitance at
HFXOUT terminal(5) (6)
Oscillator fault frequency(7) (8)
2
pF
400
700 kHz
(4) Does not include programable start-up counter.
(5) This represents all the parasitic capacitance present at the HFXIN and HFXOUT terminals, respectively, including parasitic bond and
package capacitance. The effective load capacitance, CL,eff can be computed as CIN x COUT / (CIN + COUT), where CIN and COUT
is the total capacitance at the HFXIN and HFXOUT terminals, respectively.
(6) Requires external capacitors at both terminals to meet the effective load capacitance specified by crystal manufacturers. Recommended
effective load capacitance values supported are 14 pF, 16 pF, and 18 pF. Maximum shunt capacitance of 7 pF. Because the PCB adds
additional capacitance, it must also be considered in the overall capacitance. TI recommends verifying that the recommended effective
load capacitance of the selected crystal is met.
(7) Frequencies above the MAX specification do not set the fault flag. Frequencies in between the MIN and MAX might set the flag. A static
condition or stuck at fault condition will set the flag.
(8) Measured with logic-level input frequency but also applies to operation with crystals.
50
Specifications
Copyright © 2015–2016, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: MSP432P401R MSP432P401M