English
Language : 

THS6184_16 Datasheet, PDF (3/39 Pages) Texas Instruments – DUAL-PORT, LOW-POWER DIFFERENTIAL xDSL LINE DRIVER AMPLIFIERS
THS6184
www.ti.com ................................................................................................................................................. SLLS635D – AUGUST 2005 – REVISED JANUARY 2009
PACKAGED DEVICES(2)
THS6184RHFT
THS6184RHFR
THS6184PWP
THS6184PWPR
PACKAGING/ORDERING INFORMATION(1)
DEVICE MARKING
PACKAGE TYPE
6184
QFN-24
THS6184
PowerPAD™ HTSSOP-20
TRANSPORT MEDIA, QUANTITY
Tape and reel, 250
Tape and reel, 3000
Rails, 70
Tape and reel, 2000
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com.
(2) The thermal pad is electrically isolated from all other pins.
PIN CONFIGURATION
RHF Package
(Top View)
PWP Package
(Top View)
D1 IN+
D2 IN+
GND
IADJ
NC
D3 IN+
D4 IN+
24 23 22 21 20
1
19
2
18
3
TM
17
4
erPAD
16
5
Pow
15
6
14
7
13
8 9 10 11 12
D1 IN−
D2 IN−
D2 OUT
D3 OUT
D3 IN−
D4 IN−
D4 OUT
BIAS-1/D1D2
BIAS-2/D1D2
D1 IN+
D2 IN+
GND
IADJ
D3 IN+
D4 IN+
BIAS-2/D3D4
BIAS-1/D3D4
1
20
2
19
3
18
4
17
TM
5
6
PowerPAD
16
15
7
14
8
13
9
12
10
11
VS−
D1 OUT
D1 IN−
D2 IN−
D2 OUT
D3 OUT
D3 IN−
D4 IN−
D4 OUT
VS+
See Notes
NC − No internal connection
See Notes
A. The THS6184 defaults to the FULL BIAS state if no signal is present on the BIAS pins.
B. The PowerPAD is electrically isolated from all other pins and can be connected to any potential voltage range from
VS– to VS+. Typically, the PowerPAD is connected to the GND plane as this plane tends to be physically the largest
and able to dissipate the most amount of heat.
C. The GND pin range is from VS– to (VS+ – 2.5 V).
D. The IADJ (RHF pin 4, PWP pin 6) must be connected to GND (RHF pin 3, PWP pin 5) for full bias as used in the
specification tables.
RECOMMENDED OPERATING CONDITIONS
Over operating free-air temperature range (unless otherwise noted).
VS– to VS+
TA
TJ
Dual supply
Supply voltage
Single supply
Operating free-air temperature
Operating junction temperature, continuous operating temperature
Copyright © 2005–2009, Texas Instruments Incorporated
Product Folder Link(s): THS6184
MIN MAX UNIT
±4 ±16
V
8
32
–40
85
°C
–40 130
Submit Documentation Feedback