www.ti.com
7.6.3 Address: 0x02
Figure 15. 0x02
7
DEV_ACTIVE[0
]
RO-0
6
STDBY[0]
RO-0
BIT FIELD
7 DEV_ACTIVE
6 STDBY
5 DIAG_ACTIVE
4 FAULT
3 LOAD_SHORT
2 LOAD_OPEN
1 LOAD_SHORT_GND
0 LOAD_SHORT_VDD
5
DIAG_ACTIVE[
0]
RO-0
4
FAULT[0]
RO-0
3
2
LOAD_SHORT[ LOAD_OPEN[0
0]
]
RO-0
RO-0
1
LOAD_SHORT
_GND[0]
RO-0
0
LOAD_SHORT
_VDD[0]
RO-0
Table 6. Address: 0x02
TYPE
RO
RO
RO
RO
RO
RO
RO
RO
DEFAULT DESCRIPTION
0
Shows the device status (active or shutdown).
0
Device is shutdown.
1
Device is active.
0
Shows the device standby status.
0
Device is not on standby.
1
Device is on standby.
0
Shows the status of the diagnositcs engine.
0
Not performing load diagnostics.
1
Performing load diagnostics.
0
Shows if a fault has occured on the system. Either over-voltage, under-voltage, over-current,
over-temperature.
0
No fault has occured.
1
A fault has occured.
0
Shows whether the output is shorted.
0
OUT+ is not shorted to OUT-.
1
OUT+ is shorted to OUT-.
0
Shows whether the output has a proper load connected.
0
A proper load is connected between OUT+ and OUT-.
1
There is an open connection between OUT+ and OUT-.
0
Shows whether the output is shorted to GND.
0
Output is not shorted to GND.
1
Either OUT+ or OUT- is shorted to GND.
0
Shows whether the output is shorted to VDD.
0
Output is not shorted to VDD.
1
Either OUT+ or OUT- is shorted to VDD.