TCM29C23_12 Datasheet, PDF (10/20 Pages) Texas Instruments – VARIABLE-FREQUENCY PCM OR DSP INTERFACE | |||
|
◁ |
TCM29C23, TCM129C23
VARIABLE-FREQUENCY PCM OR DSP INTERFACE
SCTS029B â AUGUST 1989 â REVISED NOVEMBER 1996
PARAMETER MEASUREMENT INFORMATION
CLK, CLKR, and CLKX selection requirements for DSP-based applications
CLK, CLKR, and CLKX must be selected as follows:
CLKSEL
â5 V
0V
5V
CLK, CLKR, CLKX
(BETWEEN 1 MHz to 3 MHz)
= (256) Ã (frame-sync frequency)
= (193) Ã (frame-sync frequency)
= (192) Ã (frame-sync frequency)
e.g., for frame-sync frequency = 16 kHz
CLKSEL
â5 V
0V
5V
CLK, CLKR, CLKX
(BETWEEN 1 MHz to 3 MHz)
= 4.096 MHz
= 3.088 MHz
= 3.072 MHz
10
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |