English
Language : 

BQ26220 Datasheet, PDF (9/19 Pages) Texas Instruments – HIGH PERFORMANCE BATTERY MONITOR IC WITH COULOMB COUNTER, VOLTAGE AND TEMPERATURE MEASUREMENT
bq26220
SLUS521B − AUGUST 2002 − REVISED FEBRUARY 2004
APPLICATION INFORMATION
Table 2. WOE Thresholds
WOE3–1 (HEX)
0h
1h
2h
3h
4h
5h
6h
7h
VWOE (mV)
n/a
3.516
1.758
1.172
0.879
0.703
0.586
0.502
Table 3. Operational States
MODE
Normal
Sleep
Hibernate
ACTIVE REGISTERS
CCR, DCR, CTC, DTC, SDR
SDR
No active registers
hibernate mode operation
The bq26220 enters hibernate mode when Vcc drops below the POR threshold, V(POR). In this mode, the
bq26220 draws current from the RBI pin to maintain RAM data. The bq26220 exits hibernate mode only when
Vcc is raised above the POR threshold.
current sense offset calibration and compensation
The bq26220 automatically and continuously compensates for V(SRP) − V(SRN) offset. No host calibration or
compensation is required.
gas gauge control registers
The host maintains the charge and discharge and the self-discharge count registers (CCR, CTC, DCR, DTC,
and SCR). To facilitate this maintenance, the bq26220 CLR register resets the specific counter or register pair
to zero. The host system clears a register by writing the corresponding register bit to 1. When the bq26220
completes the reset, the corresponding bit in the CLR register is automatically reset to 0. Clearing the DTC or
CTC registers clears the MODE register bits STC/STD and sets the CTC/DTC count rates to the default value
of 1.138 counts per second.
device temperature measurement
The bq26220 reports die temperature in units of oK through register pair TMPH−TMPL. Refer to the TMP
register description for more details.
www.ti.com