English
Language : 

CC430F613X_12 Datasheet, PDF (84/121 Pages) Texas Instruments – MSP430™ SoC with RF Core
CC430F613x
CC430F612x
CC430F513x
ECCN 5E002 TSPA - Technology / Software Publicly Available
SLAS554F – MAY 2009 – REVISED DECEMBER 2011
www.ti.com
Typical Output Power, 315 MHz(1)
PARAMETER
PATABLE Setting
Output power,
315 MHz
0xC0 (max)
0xC4 (10 dBm)
0xC6 (default)
0x51 (0 dBm)
0x29 (-6 dBm)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
11.9
11.8
11.8
10.3
10.3
10.3
9.3
dBm
0.7
0.6
0.7
-6.8
-5.6
-5.3
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 48).
Typical Output Power, 433 MHz(1)
PARAMETER
PATABLE Setting
Output power,
433 MHz
0xC0 (max)
0xC4 (10 dBm)
0xC6 (default)
0x50 (0 dBm)
0x2D (-6 dBm)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
12.6
12.6
12.6
10.3
10.2
10.2
10.0
dBm
0.3
0.3
0.3
-6.4
-5.4
-5.1
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 48).
Typical Output Power, 868 MHz(1)
PARAMETER
PATABLE Setting
0xC0 (max)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
11.9 11.2 10.5 11.9 11.2 10.5 11.9 11.2 10.5
Output power,
868 MHz
0xC3 (10 dBm)
0xC6 (default)
0x8D (0 dBm)
10.8 10.1 9.4 10.8 10.1 9.4 10.7 10.1 9.4
8.8
dBm
1.0 0.3 -0.3 1.1 0.3 -0.3 1.1 0.3 -0.3
0x2D (-6 dBm)
-6.5 -6.8 -7.3 -5.3 -5.8 -6.3 -4.9 -5.4 -6.0
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 48).
Typical Output Power, 915 MHz(1)
PARAMETER
PATABLE Setting
0xC0 (max)
VCC
2.0 V
3.0 V
3.6 V
UNIT
TA -40°C 25°C 85°C -40°C 25°C 85°C -40°C 25°C 85°C
12.2 11.4 10.6 12.1 11.4 10.7 12.1 11.4 10.7
Output power,
915 MHz
0xC3 (10 dBm)
0xC6 (default)
0x8D (0 dBm)
11.0 10.3 9.5 11.0 10.3 9.5 11.0 10.3 9.6
8.8
dBm
1.9 1.0 0.3 1.9 1.0 0.3 1.9 1.1 0.3
0x2D (-6 dBm)
-5.5 -6.0 -6.5 -4.3 -4.8 -5.5 -3.9 -4.4 -5.1
(1) All measurement results are obtained using the EM430F6137RF900 with BOM according to tested frequency range (see Table 48).
84
Submit Documentation Feedback
Copyright © 2009–2011, Texas Instruments Incorporated