Recommended Operating Conditions (continued)
NAME
DESCRIPTION
CONDITION
MIN
NOM
MAX
UNIT
Differential
Clock Input
Voltage
Differential input voltage, SATA_REFCLKP and
SATA_REFCLKN
250
mV
Transition
Time
tt
Transition time, 10%-90%, All Inputs (unless otherwise
specified in the electrical data sections)
0.25P (4)
ns
CVDD = 1.3V
operating point
0
456
Commercial temperature grade
CVDD = 1.2V
operating point
0
(default)
CVDD = 1.1V
operating point
0
375
MHz
200
Operating
Frequency
FPLL0_SYSCLK6
CVDD = 1.0V
operating point
0
100
CVDD = 1.3V
operating point
0
456
Extended temperature grade (A
CVDD = 1.2V
operating point
0
suffix)
CVDD = 1.1V
operating point
0
375
MHz
200
CVDD = 1.0V
operating point
0
100
(4) Where P = the period of the applied signal. Maintaining transition times as fast as possible is recommended to improve noise immunity
on input signals.
Copyright © 2010, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Link(s): AM1808
Device Operating Conditions
67