POWER-DOWN REGISTER (Read/Write)
NOTE: After power-on or reset, all bits in the Power-Down Register are cleared to '0', and all the components
controlled by this register are in the powered-down or Off state. To avoid loss of alarm data during power-down
of the ADC, change the ADC conversion to direct mode (see ADC Control Register) before power-down and do
not issue a convert command while the ADC is powered down. The Power-Down Register must be set properly
before operating the ADC, DAC, precision current source, and reference of this device. It is recommended that
the Power-Down Register be programmed after all other registers have been initialized.
The Power-Down Register allows the host to manage power dissipation of the AMC7823. When not required, the
ADC, the precision current source, the reference buffer amplifier or any of the DACs may be put in power-down
mode to reduce current drain from the supply. Bits in the Power-Down Register control this power-down function.
Bit
15
MSB Bit 14
PAD PDAC7
C
X : Don't Care
Bit 13
PDAC
6
Bit 12
PDAC
5
Bit 11
PDAC4
Bit 10
PDAC
3
Bit 9
PDAC2
Bit 8 Bit 7 Bit 6
PDAC1 PDAC0 PTS
Bit 5
PREFB
Bit 4 Bit 3 Bit 2 Bit 1
XXXX
Bit 0
LSB
X
PADC
PDAC-n
(n = 0, 1, 2, 3, 4, 5, 6, 7)
PTS
PREFB
ADC power-down control bit.
PADC = '0': The ADC is in power-down mode and ADC conversion is halted.
PADC = '1': The ADC is in normal operating mode.
DAC-n output buffer amplifier power-down control bit.
PDAC-n = '0': DAC-n output buffer amplifier is in power-down mode. The output pin
of DAC-n is internally switched from the buffer output to analog ground through an
internal 5kΩ resistor. Each DAC output buffer may be independently powered down.
(See the DAC Operation section for details.)
PDAC-n = '1' and PREFB = '1': DAC-n is in normal operating mode.
Precision current source power-down control bit.
PTS = '0': Precision current source is in power-down mode and the current output is
zero.
PTS = '1': Precision current source is in normal operating mode (see the Precision
Current Source section for details).
Reference buffer amplifier power-down control bit. This bit controls the power-down
condition of the amplifier that supplies a buffered reference voltage to all DAC-n
resistor strings and to the precision current source. This bit also provides
configuration information to the precision current source (see the Precision Current
Source Configuration table, Table 7).
PREFB = '0': Reference buffer amplifier is in power-down mode. All DACs are
inoperative. The precision current source may be used only if GREF = '0' (see the
Precision Current Source Configuration table, Table 7).
PREFB = '1': Reference buffer amplifier is powered on. This mode is required for
any DAC-n operation. The precision current source may be used with either value of
GREF.
46