English
Language : 

MSP430F2618-EP Datasheet, PDF (37/92 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F2618- EP
MIXED SIGNAL MICROCONTROLLER
SLAS632 -- DECEMBER 2008
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
main DCO characteristics
D All ranges selected by RSELx overlap with RSELx + 1: RSELx = 0 overlaps RSELx = 1, ... RSELx = 14
overlaps RSELx = 15.
D DCO control bits DCOx have a step size as defined by parameter SDCO.
D Modulation control bits MODx select how often fDCO(RSEL,DCO+1) is used within the period of 32 DCOCLK
cycles. The frequency fDCO(RSEL,DCO) is used for the remaining cycles. The frequency is an average equal
to:
faverage
=
MOD
32 × fDCO(RSEL,DCO) × fDCO(RSEL,DCO+1)
× fDCO(RSEL,DCO)+(32−MOD) × fDCO(RSEL,DCO+1)
DCO frequency
PARAMETER
TEST CONDITIONS
RSELx < 14
VCC
MIN
1.8
VCC
Supply voltage
RSELx = 14
2.2
RSELx = 15
3.0
fDCO(0,0)
fDCO(0,3)
fDCO(1,3)
fDCO(2,3)
fDCO(3,3)
fDCO(4,3)
fDCO(5,3)
fDCO(6,3)
fDCO(7,3)
fDCO(8,3)
fDCO(9,3)
fDCO(10,3)
fDCO(11,3)
fDCO(12,3)
fDCO(13,3)
fDCO(14,3)
fDCO(15,3)
fDCO(15,7)
SRSEL
DCO frequency (0, 0)
RSELx = 0, DCOx = 0, MODx = 0
2.2 V/3 V
0.06
DCO frequency (0, 3)
RSELx = 0, DCOx = 3, MODx = 0
2.2 V/3 V
0.07
DCO frequency (1, 3)
RSELx = 1, DCOx = 3, MODx = 0
2.2 V/3 V
0.10
DCO frequency (2, 3)
RSELx = 2, DCOx = 3, MODx = 0
2.2 V/3 V
0.14
DCO frequency (3, 3)
RSELx = 3, DCOx = 3, MODx = 0
2.2 V/3 V
0.20
DCO frequency (4, 3)
RSELx = 4, DCOx = 3, MODx = 0
2.2 V/3 V
0.28
DCO frequency (5, 3)
RSELx = 5, DCOx = 3, MODx = 0
2.2 V/3 V
0.39
DCO frequency (6, 3)
RSELx = 6, DCOx = 3, MODx = 0
2.2 V/3 V
0.54
DCO frequency (7, 3)
RSELx = 7, DCOx = 3, MODx = 0
2.2 V/3 V
0.80
DCO frequency (8, 3)
RSELx = 8, DCOx = 3, MODx = 0
2.2 V/3 V
1.10
DCO frequency (9, 3)
RSELx = 9, DCOx = 3, MODx = 0
2.2 V/3 V
1.60
DCO frequency (10, 3) RSELx = 10, DCOx = 3, MODx = 0
2.2 V/3 V
2.50
DCO frequency (11, 3) RSELx = 11, DCOx = 3, MODx = 0
2.2 V/3 V
3.00
DCO frequency (12, 3) RSELx = 12, DCOx = 3, MODx = 0
2.2 V/3 V
4.30
DCO frequency (13, 3) RSELx = 13, DCOx = 3, MODx = 0
2.2 V/3 V
6.00
DCO frequency (14, 3) RSELx = 14, DCOx = 3, MODx = 0
2.2 V/3 V
8.60
DCO frequency (15, 3) RSELx = 15, DCOx = 3, MODx = 0
3V
12.0
DCO frequency (15, 7) RSELx = 15, DCOx = 7, MODx = 0
3V
16.0
Frequency step between
range RSEL and RSEL+1
SRSEL = fDCO(RSEL+1,DCO)/fDCO(RSEL,DCO)
2.2 V/3 V
TYP MAX UNIT
3.6
3.6 V
3.6
0.14 MHz
0.17 MHz
0.20 MHz
0.28 MHz
0.40 MHz
0.54 MHz
0.77 MHz
1.06 MHz
1.50 MHz
2.10 MHz
3.00 MHz
4.30 MHz
5.50 MHz
7.30 MHz
9.60 MHz
13.9 MHz
18.5 MHz
26.0 MHz
1.55 ratio
SDCO
Frequency step between
tap DCO and DCO+1
SDCO = fDCO(RSEL,DCO+1)/fDCO(RSEL,DCO)
2.2 V/3 V
1.05 1.08 1.12 ratio
Duty cycle
Measured at P1.4/SMCLK
2.2 V/3 V
40
50
60 %
 POST OFFICE BOX 655303 DALLAS, TEXAS 75265
37