English
Language : 

MSP430F2618-EP Datasheet, PDF (33/92 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F2618- EP
MIXED SIGNAL MICROCONTROLLER
SLAS632 -- DECEMBER 2008
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
POR/brownout reset (BOR) (see Notes 1 and 2)
PARAMETER
TEST CONDITIONS
VCC
MIN TYP MAX UNIT
VCC(start) operating voltage
dVCC/dt ± 3 V/s
0.7 ¢ V(B_IT--)
V
V(B_IT--)
negative going VCC reset threshold voltage
dVCC/dt ± 3 V/s
1.71 V
Vhys(B_IT--) VCC reset threshold hysteresis
dVCC/dt ± 3 V/s
70 130 210 mV
td(BOR)
BOR reset release delay time
2000 s
treset
Pulse length at RST/NMI pin to accept a reset
2.2 V / 3 V
2
s
NOTES: 1. The current consumption of the brownout module is included in the ICC current consumption data. The voltage level
V(B_IT--) + Vhys(B_IT--) is  1.8 V.
2. During power up, the CPU begins code execution following a period of td(BOR) after VCC = V(B_IT--) + Vhys(B_IT--). The default DCO
settings must not be changed until VCC  VCC(MIN), where VCC(min) is the minimum supply voltage for the desired operating
frequency.
VCC
V(B_IT-)
VCC(Start)
Vhys(B_IT-)
1
0
td(BOR)
Figure 9. POR/Brownout Reset (BOR) vs Supply Voltage
 POST OFFICE BOX 655303 DALLAS, TEXAS 75265
33