English
Language : 

MSP430F2618-EP Datasheet, PDF (30/92 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F2618- EP
MIXED SIGNAL MICROCONTROLLER
SLAS632 -- DECEMBER 2008
Schmitt-trigger inputs -- ports P1 through P8, RST/NMI, JTAG, XIN, and XT2IN (see Note 1)
PARAMETER
VIT+ Positive-going input threshold voltage
VIT-- Negative-going input threshold voltage
Vhys Input voltage hysteresis (VIT+ -- VIT--)
TEST CONDITIONS
VCC
2.2 V
3V
2.2 V
3V
2.2 V
3V
MIN
0.45 VCC
1.0
1.35
0.25 VCC
0.55
0.75
0.2
0.3
TYP
MAX
0.75 VCC
1.65
2.25
0.55 VCC
1.2
1.65
1.0
1.0
UNIT
V
V
V
RPull Pullup/pulldown resistor
CI
Input capacitance
NOTE 1: XIN and XT2IN in bypass mode only.
Pullup: VIN = VSS,
Pulldown: VIN = VCC
VIN = VSS or VCC
20
35
5
50 kΩ
pF
inputs -- ports P1 and P2
PARAMETER
tint
External interrupt timing
TEST CONDITIONS
Port P1, P2: P1.x to P2.x, external trigger pulse width to
set the interrupt flag (see Note 1)
VCC
2.2 V/3 V
MIN MAX UNIT
20
ns
NOTE 1: The external signal sets the interrupt flag every time the minimum t(int) parameters are met. It may be set with trigger signals shorter
than t(int).
leakage current -- ports P1 through P8 (see Note 1 and 2)
PARAMETER
TEST CONDITIONS
VCC
MIN MAX UNIT
Ilkg (Px.x)
High-impedance leakage current
see Notes 1 and 2
2.2 V/3 V
50 nA
NOTES: 1. The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
2. The leakage of digital port pins is measured individually. The port pin is selected for input and the pullup/pulldown resistor is disabled.
30