English
Language : 

GC5318 Datasheet, PDF (33/45 Pages) Texas Instruments – HIGH-DENSITY DIGITAL UPCONVERTER
www.ti.com
GC5318
HIGH-DENSITY DIGITAL UPCONVERTER
SLWS187 – JULY 2006
Variable Name
comp_pmeter0_interval_lsb
Type
D
Page Address
1C00
04
LSB
Position
0
comp_pmeter0_interval_msb D 1C00
05
0
comp_pmeter1_count_lsb
D 1C00
06
0
comp_pmeter1_count_msb D 1C00
07
0
comp_pmeter1_sync_delay D 1C00
07
7
comp_pmeter1_interval_lsb D 1C00
08
0
comp_pmeter1_interval_msb D 1C00
09
0
comp_pmeter2_count_lsb
D 1C00
0A
0
comp_pmeter2_count_msb D 1C00 0B
0
comp_pmeter2_sync_delay D 1C00 0B
7
comp_pmeter2_interval_lsb D 1C00 0C
0
comp_pmeter2_interval_msb D 1C00 0D
0
comp_pmeter3_count_lsb
D 1C00
0E
0
comp_pmeter3_count_msb D 1C00
0F
0
comp_pmeter3_sync_delay D 1C00
0F
7
comp_pmeter3_interval_lsb D 1C00
10
0
comp_pmeter3_interval_msb D 1C00
11
0
duc_counter_lsb
D 1C00 1A
0
duc_counter_msb
D 1C00 1B
0
ssel_duc_counter
U 1C00 1C
8
duc_counter_width
D 1C00 1C
0
ssel_comp_pmeter_0
U 1C00 1D
12
ssel_comp_pmeter_1
U 1C00 1D
8
ssel_comp_pmeter_2
U 1C00 1D
4
ssel_comp_pmeter_3
U 1C00 1D
0
ssel_txsync_out
U 1C00 1E
0
Bit
Width
16
5
16
5
9
16
5
16
5
9
16
5
16
5
9
16
5
16
16
3
8
3
3
3
3
3
Default
Description
0 This is the interval over which the integration is
restarted and must be greater than the
integration count. The interval start counter and
RMS power accumulation is started at the sync
pulse after the programmed delay and every
time the interval counter reaches its limit. Bits
0–15
0 Bits 16–20 of the interval over which the
integration is restarted. (Used in conjunction with
the previous variable.)
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
0 See description for pmeter0
65535
32-bit interval timer common to all DUC sync
inputs. This timer may be programmed to any
interval count, and each DUC synchronization
input can select this counter as a source. This
counter increments on every TXCLK rising edge.
Bits 0–15
65535 Bits 16-31 of the above mentioned 32-bit interval
timer.
0 Selects the sync source for the DUC sync
counter.
0 Sets the width of the counter generated sync
pulse in TX clock cycles, from 1 to 256. The
width of this pulse must be long enough to be
captured by the slowest block to use the DUC
counter sync.
0 Selects the sync source for composite power
meter 0.
0 Selects the sync source for composite power
meter 1.
0 Selects the sync source for composite power
meter 2.
0 Selects the sync source for composite power
meter 3.
0 Selects the sync source for the TXSYNC_OUT
pin.
GC5318 Programming
33