English
Language : 

TLC5949 Datasheet, PDF (22/51 Pages) Texas Instruments – 16-Channel, 12-Bit, ES-PWM, Full Self-Diagnosis LED Driver for 7-Bit Global BC LED Lamp
TLC5949
SBVS219A – DECEMBER 2012 – REVISED DECEMBER 2012
www.ti.com
Enhanced Spectrum (ES) PWM Control
In this PWM control, the total display period is divided into 32 display segments. The total display period is the
time from the first GS clock (GSCLK) to the 4096th GSCLK input after the BLANK bit is set to '0'. Each display
segment has a maximum of 128 GSCLKs. The OUTn on-time changes, depending on the 12-bit GS data. Refer
to Table 4 for the sequence of information and to Figure 23 for the timing information.
GS DATA
DECIMAL
HEX
0
000h
1
001h
2
002h
3
003h
4
004h
5
005h
6
006h
—
—
31
01Fh
32
020h
33
021h
—
—
63
03Fh
64
040h
65
041h
—
—
4063
4064
4065
—
4094
4095
EDFh
FE0h
FE1h
—
FFEh
FFFh
Table 4. ES PWM Drive Turn-On Time Length
OUTn DRIVER OPERATION
Does not turn on
Turns on for one GSCLK period in the first display segment
Turns on for one GSCLK period in the first and 17th display segments
Turns on for one GSCLK period in the first, 17th, and 9th display segments
Turns on for one GSCLK period in the first, 17th, 9th, and 25th display segments
Turns on for one GSCLK period in the first, 17th, 9th, 25th, and 5th display segments
Turns on for one GSCLK period in the first, 17th, 9th, 25th, 5th, and 21th display segments
The number of display segments where OUTn is turned on for one GSCLK is incremented by
increasing GS data in the following order:
1 > 17 > 9 > 25 5 > 21 > 13 > 29 > 3 > 19 > 11 > 27 > 7 > 23 > 15 > 31 > 2 > 18 > 10 > 26 > 6 >
22 > 14 > 30 > 4 > 20 > 12 > 28 > 8 > 24 > 16 > 32.
Turns on for one GSCLK period in the first to 31st display segments, but does not turn on in the
32nd display segment
Turns on for one GSCLK period in all display segments (first to 32nd)
Turns on for two GSCLK periods in the first display period and for one GSCLK period in all other
display periods
The number of display segments where OUTn is turned on for one GSCLK is incremented by
increasing GS data in the following order:
1 > 17 > 9 > 25 5 > 21 > 13 > 29 > 3 > 19 > 11 > 27 > 7 > 23 > 15 > 31 > 2 > 18 > 10 > 26 > 6 >
22 > 14 > 30 > 4 > 20 > 12 > 28 > 8 > 24 > 16 > 32.
Turns on for two GSCLK periods in the first to 31st display segments and turns on one GSCLK
period in the 32nd display segment
Turns on for two GSCLK periods in all display segments (first to 32nd)
Turns on for three GSCLK periods in the first display segment and for two GSCLK periods in all
other display segments
The number of display segments where OUTn is turned on for one GSCLK is incremented by
increasing GS data in the following order:
1 > 17 > 9 > 25 5 > 21 > 13 > 29 > 3 > 19 > 11 > 27 > 7 > 23 > 15 > 31 > 2 > 18 > 10 > 26 > 6 >
22 > 14 > 30 > 4 > 20 > 12 > 28 > 8 > 24 > 16 > 32.
Turns on for 127 GSCLK periods in the first to 31st display segments, but only turns on for 126
GSCLK periods in the 32nd display segment
Turns on for 127 GSCLK periods in all display segments (first to 32nd)
Turns on for 128 GSCLK periods in the first display period and for 127 GSCLK periods in the
second to 32nd display segments
—
Turns on for 128 GSCLK periods in the first to 15th and 17th to 31st display segments; also turns
on for 127 GSCLK periods in the 16th and 32nd display segments.
Turns on for 128 GSCLK periods in the first to 31st display segments but only turns on for 127
GSCLK periods in the 32nd display segment
22
Submit Documentation Feedback
Product Folder Links: TLC5949
Copyright © 2012, Texas Instruments Incorporated