English
Language : 

THS10064 Datasheet, PDF (17/41 Pages) Texas Instruments – 10-BIT 6 MSPS, SIMULTANEOUS SAMPLING ANALOG-TO-DIGITAL CONVERTER
THS10064
10-BIT 6 MSPS, SIMULTANEOUS SAMPLING
ANALOG-TO-DIGITAL CONVERTER
SLAS255 – DECEMBER 1999
initialization of the THS10064
The initialization of the THS10064 should be done according to the configuration flow shown in Figure 11.
Start
Use Default
No
Values?
Yes
Write 0x401 to
THS10064
(Set Reset Bit in CR1)
Write 0x401 to
THS10064
(Set Reset Bit in
CR1)
Clear RESET By
Writing 0x400 to
CR1
Write The User
Configuration to
CR0
Write The User
Configuration to
CR1 (Can Include
FIFO Reset, Must
Exclude RESET)
Continue
Figure 11. THS10064 Configuration Flow
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
17