THS10064 Datasheet, PDF (1/41 Pages) Texas Instruments – 10-BIT 6 MSPS, SIMULTANEOUS SAMPLING ANALOG-TO-DIGITAL CONVERTER
THS10064
10-BIT 6 MSPS, SIMULTANEOUS SAMPLING
ANALOG-TO-DIGITAL CONVERTER
SLAS255 – DECEMBER 1999
features
applications
D Simultaneous Sampling of 4 Single-Ended
Signals or 2 Differential Signals or
Combination of Both
D Integrated 16-Word FIFO
D Signal-to-Noise and Distortion Ratio: 59 dB
at fI = 2 MHz
D Differential Nonlinearity Error: ±1 LSB
D Integral Nonlinearity Error: ±1 LSB
D Auto-Scan Mode for 2, 3, or 4 Inputs
D 3-V or 5-V Digital Interface Compatible
D Low Power: 216 mW Max
D 5-V Analog Single Supply Operation
D Internal Voltage References . . . 50 PPM/°C
and ±5% Accuracy
D Parallel µC/DSP Interface
D Radar Applications
D Communications
D Control Applications
D High-Speed DSP Front-End
D Automotive Applications
DA (TSSOP) PACKAGE
(TOP VIEW)
D0 1
D1 2
D2 3
D3 4
D4 5
D5 6
BVDD 7
BGND 8
32 AINP
31 AINM
30 BINP
29 BINM
28 REFIN
27 REFOUT
26 REFP
25 REFM
description
The THS10064 is a CMOS, low-power, 10-bit,
6 MSPS analog-to-digital converter (ADC). The
speed, resolution, bandwidth, and single-supply
operation are suited for applications in radar,
imaging, high-speed acquisition, and
communications. A multistage pipelined
architecture with output error correction logic
D6 9
D7 10
D8 11
D9 12
RA0 13
RA1 14
CONV_CLK (CONVST) 15
DATA_AV 16
24 AGND
23 AVDD
22 CS0
21 CS1
20 WR (R/W)
19 RD
18 DVDD
17 DGND
provides for no missing codes over the full
operating temperature range. Internal control
registers are used to program the ADC into the desired mode. The THS10064 consists of four analog inputs,
which are sampled simultaneously. These inputs can be selected individually and configured to single-ended
or differential inputs. An integrated 16 word deep FIFO allows the storage of data in order to improve data
transfers to the processor. Internal reference voltages for the ADC (1.5 V and 3.5 V) are provided.
An external reference can also be chosen to suit the dc accuracy and temperature drift requirements of the
application. Two different conversion modes can be selected. In single conversion mode, a single and
simultaneous conversion of up to four inputs can be initiated by using the single conversion start signal
(CONVST). The conversion clock in single conversion mode is generated internally using a clock oscillator
circuit. In continuous conversion mode, an external clock signal is applied to the CONV_CLK input of the
THS10064. The internal clock oscillator is switched off in continuous conversion mode.
The THS10064C is characterized for operation from 0°C to 70°C, and the THS10064I is characterized for
operation from –40°C to 85°C.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
Copyright © 1999, Texas Instruments Incorporated
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
1