English
Language : 

LSM330DLC Datasheet, PDF (50/66 Pages) STMicroelectronics – iNEMO inertial module: 3D accelerometer and 3D gyroscope
Register descriptions
LSM330DLC
8.18 CLICK_CFG _A (38h)
Table 51. CLICK_CFG_A register
--
--
ZD
ZS
YD
YS
XD
XS
Table 52.
ZD
ZS
YD
YS
XD
XS
CLICK_CFG_A description
Enable interrupt double CLICK on Z axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on Z axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt double CLICK on Y axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on Y axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt double CLICK on X axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK on X axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
8.19 CLICK_SRC_A (39h)
Table 53. CLICK_SRC_A register
--
IA
DCLICK SCLICK Sign
Z
Y
X
Table 54.
IA
DCLICK
SCLICK
Sign
Z
CLICK_SRC_A description
Interrupt active. Default value: 0
(0: no interrupt has been generated; 1: one or more interrupts have been generated)
Double CLICK-CLICK enable. Default value: 0 (0:double CLICK-CLICK detection dis-
able, 1: double CLICK-CLICK detection enable)
Single CLICK-CLICK enable. Default value: 0 (0:Single CLICK-CLICK detection dis-
able, 1: single CLICK-CLICK detection enable)
CLICK-CLICK Sign. 0: positive detection, 1: negative detection
Z CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Z High event has occurred)
50/66