CABLE TYPE
RG-62 Belden #86262
RG-59/U Belden #89108
RG-11/U Belden #89108
IBM Type 1* Belden #89688
IBM Type 3* Telephone Twisted
Pair Belden #1155A
COMCODE 26 AWG Twisted
Pair Part #105-064-703
Table 1 - Typical Media
NOMINAL
IMPEDANCE
ATTENUATION PER 1000 FT.
AT 5 MHz
93
5.5dB
75
7.0dB
75
5.5dB
150
7.0dB
100
17.9dB
105
16.0dB
*Non-plenum-rated cables of this type are also available.
Note: For more detailed information on Cabling options including RS-485, transformer-coupled RS-485
and Fiber Optic interfaces, please refer to TN7-5 – Cabling Guidelines for the COM20020 ULANC,
available from Standard Microsystems Corporation.
FUNCTIONAL DESCRIPTION
MICROSEQUENCER
is stored in the ROM and the instructions are
The COM20019 contains an internal fetched and then placed into the instruction
microsequencer which performs all of the control registers. One register holds the opcode, while
operations necessary to carry out the ARCNET the other holds the immediate data. Once the
protocol. It consists of a clock generator, a 544 x instruction is fetched, it is decoded by the internal
8 ROM, a program counter, two instruction instruction decoder, at which point the COM20019
registers, an instruction decoder, a no-op proceeds to execute the instruction. When a no-
generator, jump logic, and reconfiguration logic.
op instruction is encountered, the microsequencer
enters a timed loop and the program counter is
The COM20019 derives a 625 kHz and a 312.5 temporarily stopped until the loop is complete.
kHz clock from the output clock of the Clock When a jump instruction is encountered, the
Multiplier. These clocks provide the rate at which program counter is loaded with the jump address
the instructions are executed within the from the ROM. The COM20019 contains an
COM20019. The 625 kHz clock is the rate at internal reconfiguration timer which interrupts the
which the program counter operates, while the microsequencer if it has timed out. At this point
312.5 kHz clock is the rate at which the the program counter is cleared and the
instructions are executed. The microprogram MYRECON bit of the Diagnostic Status Register is
set.
23