English
Language : 

GS2972 Datasheet, PDF (94/125 Pages) Semtech Corporation – 3G/HD/SD-SDI Serializer with Complete SMPTE Audio & Video Support
Table 4-34: Video Core Configuration and Status Registers (Continued)
Address
Register Name
Bit Name
RSVD
ANC_UES_PGM
ANC_IDA_PGM
ANC_IDH_PGM
ANC_EDA_PGM
ANC_EDH_PGM
FF_UES_PGM
003h
EDH_FLAG_PGM
FF_IDA_PGM
FF_IDH_PGM
FF_EDA_PGM
FF_EDH_PGM
AP_UES_PGM
AP_IDA_PGM
AP_IDH_PGM
AP_EDA_PGM
AP_EDH_PGM
RSVD
VD_STD
INT/PROGB
004h
DATA_FORMAT
CONV_372_LOCKED
STD_LOCK
V_LOCK
H_LOCK
Bit Description
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
15-10
9-5
4
3
2
1
0
Reserved.
Ancillary data - unknown error
status flag.
Ancillary data - internal error
detected already flag.
Ancillary data - internal error
detected here flag.
Ancillary data - error detected
already flag.
Ancillary data - error detected
here flag.
EDH Full Field - unknown error
status flag.
EDH Full Field - internal error
detected already flag.
EDH Full Field - internal error
detected here flag.
EDH Full Field - error detected
already flag.
EDH Full Field - error detected
here flag.
EDH Active Picture - unknown
error status flag.
EDH Active Picture - internal error
detected already flag.
EDH Active Picture - internal error
detected here flag.
EDH Active Picture - error detected
already flag.
EDH Active Picture - error detected
here flag.
Reserved.
Detected video standard.
HIGH = interlaced signal
LOW = progressive signal
Convert 372 lock indication. Active
HIGH.
Standard lock indication. Active
HIGH.
Vertical lock indication. Active
HIGH.
Horizontal lock indication. Active
HIGH.
R/W Default
R
0
R
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R
0
R
0
R
0
R
0
R
0
R
0
R
0
GS2972 3G/HD/SD-SDI Serializer with Complete
SMPTE Audio & Video Support
Final Data Sheet Rev. 9
GENDOC-047479 September 2013
www.semtech.com
94 of 125