English
Language : 

S6B0755 Datasheet, PDF (43/68 Pages) Samsung semiconductor – 128 SEG / 65 COM DRIVER & CONTROLLER FOR STN LCD
128 SEG / 65 COM DRIVER & CONTROLLER FOR STN LCD
PRELIMINARY SPEC. VER. 1.0
S6B0755
Set Initial COM0 Register
Sets the initial row (COM0) of the LCD panel using the 2-byte instruction. By using this instruction, it is
possible to realize the window moving without the change of display data.
The 1st Instruction
RS
RW
0
0
The 2nd Instruction
RS
RW
0
0
DB7
0
DB7
×
DB6
1
DB6
×
DB5
0
DB5
C5
DB4
0
DB4
C4
DB3
0
DB3
C3
DB2
1
DB2
C2
DB1
×
DB1
C1
DB0
×
DB0
C0
C5
C4
C3
C2
C1
C0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
0
0
0
1
1
:
:
:
:
:
:
1
1
1
1
0
0
1
1
1
1
0
1
1
1
1
1
1
0
1
1
1
1
1
1
Initial COM0
COM0
COM1
COM2
COM3
:
COM60
COM61
COM62
COM63
Setting Initial COM0 Start
1st Instruction (Mode Setting)
2nd Instruction (Initial COM0 Setting)
Setting Initial COM0 End
end
Figure 30. Sequence for Setting the Initial COM0
40