English
Language : 

S6B0755 Datasheet, PDF (35/68 Pages) Samsung semiconductor – 128 SEG / 65 COM DRIVER & CONTROLLER FOR STN LCD
128 SEG / 65 COM DRIVER & CONTROLLER FOR STN LCD
PRELIMINARY SPEC. VER. 1.0
S6B0755
RESET CIRCUIT
Setting RESETB to "L" or Reset instruction can initialize internal function.
When RESETB becomes "L", following procedure is occurred.
Page address: 0
Column address: 0
Modify-read: OFF
Display ON / OFF: OFF
Initial display line: 0 (first)
Initial COM0 register: 0 (COM0)
Partial display duty ratio: 1/64
Icon enable/disable : 0 (disable)
Reverse display ON / OFF: OFF (normal)
n-line inversion register: 0 (disable)
Entire display ON / OFF: OFF (normal)
Power control register (VC, VR, VF) = (0, 0, 0)
DC-DC step up: 3 times converter circuit = (0, 0)
Regulator resistor select register: (R2, R1, R0) = (0, 0, 0)
Reference voltage control register: (EV5, EV4, EV3, EV2, EV1, EV0) = (1, 0, 0, 0, 0, 0)
LCD bias ratio: 1/9
SHL select: OFF (normal)
ADC select: OFF (normal)
Oscillator status: OFF
Power save mode: release
When RESET instruction is issued, following procedure is occurred.
Page address: 0
Column address: 0
Modify-read: OFF
Initial display line: 0 (First)
Regulator resistor select register: (R2, R1, R0) = (0, 0, 0)
Reference voltage control register (EV5, EV4, EV3, EV2, EV1, EV0) = (1, 0, 0, 0, 0, 0)
Other instruction registers : Not Changed
While RESETB is "L" or reset instruction is executed, no instruction except read status can be accepted. Reset
status appears at DB4. After DB4 becomes "L", any instruction can be accepted. RESETB must be connected to
the reset pin of the MPU, and initialize the MPU and this LSI at the same time. The initialization by RESETB is
essential before used.
32