S6A0092 Datasheet, PDF (27/54 Pages) Samsung semiconductor – 80 SEG / 26 COM DRIVER & CONTROLLER FOR STN LCD
80 COM / 26 COM DRIVER & CONTROLLER FOR STN LCD
S6A0092
POWER SAVE SET
RS
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
0
0
0
1
1
OS
PS
Power Save instruction field is used to control the oscillator and to set or to reset the power save mode.
OS: Oscillator ON / OFF Control Bit
When OS = "High", oscillator is turned ON.
When OS = "Low", oscillator is turned OFF (default).
PS: Power Save ON / OFF Control Bit
When PS = "High", power save mode is turned ON.
When PS = "Low", power save mode is turned OFF (default).
FUNCTION SET
RS
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
0
0
1
0
N
S
CG
N: Display Line Mode Instruction field selects 2 line or 3 line display mode
When N = "High", 3-line display mode
When N = "Low", 2-line display mode (default)
S: Data Shift Direction of Common
S sets the shift direction of common display data
When S = "High", COM right shift.
When S = "Low", COM left shift (default).
(Refer to table 9)
CG: CGRAM Enable Bit
When CG = "High", CGRAM can be accessed and you can use this RAM for eight
special character area. (00h - 07h = CGRAM font display)
When CG = "Low", CGRAM is disabled. CGROM (00h~07h) can be accessed and
the additional current consumption is saved by using this mode (default).
(00h - 07h = CGROM font display)
23