English
Language : 

S6A0092 Datasheet, PDF (24/54 Pages) Samsung semiconductor – 80 SEG / 26 COM DRIVER & CONTROLLER FOR STN LCD
S6A0092
26 COM / 80 SEG DRIVER & CONTROLLER FOR STN LCD
RETURN HOME
RS
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
0
0
0
0
0
1
-
Return Home instruction field makes cursor return home. DDRAM address is set to 00h from AC and the cursor
returns to 00h position. The contents of DDRAM are not changed.
DOUBLE HEIGHT MODE
RS
DB7
DB6
DB5
DB4
DB3
DB2
DB1
DB0
0
0
0
0
0
1
0
DH2
DH1
Double Height Mode instruction field selects double height line type.
DH2, DH1 = 00: normal display line mode (default)
01: COM1 ∼ COM16 is a double height,
COM17 ∼ COM24 is normal
10: 1) 2-line mode: normal display
2) 3-line mode: COM1 ∼ COM8 is normal
COM9 ∼ COM24 is a double height
11: normal display
Figure 10. 3-line Normal Mode Display (DH2, DH1 = 00)
20