English
Language : 

HD404369 Datasheet, PDF (90/117 Pages) Hitachi Semiconductor – 4-bit HMCS400-Series microcomputer
HD404369 Series
A/D Start Flag (ADSF: $02C, Bit 2): One-bit flag that initiates A/D conversion when set to 1. At the
completion of A/D conversion, the converted data is stored in the A/D data register and the A/D start flag is
cleared. Refer to figure 73.
A/D start flag (ADSF: $020, bit 2)
Bit
Initial value
Read/Write
Bit name
3
0
R/W
DTON
2
0
R/W
ADSF
1
0
W
WDON
0
0
R/W
LSON
A/D Start Flag (ADSF)
0
A/D conversion completed
1
A/D conversion started
DTON
Refer to the description of operating
modes
LSON
Refer to the description of operating
modes
WDON
Refer to the description of timers
Figure 73 A/D Start Flag (ADSF)
IAD Off Flag (IAOF: $021, Bit 2): By setting the IAD off flag to 1, the current flowing through the
resistance ladder can be cut off even while operating in standby or active mode, as shown in figure 74.
IAD off flag (IAOF: $021, bit 2)
Bit
Initial value
Read/Write
Bit name
3
0
R/W
RAME
2
0
R/W
IAOF
1
0
R/W
ICEF
0
0
R/W
ICSF
IAD Off Flag (IAOF)
0
IAD current flows
1
IAD current is cut off
RAME
Refer to the description of operating
modes
ICSF
Refer to the description of timers
ICEF
Refer to the description of timers
Figure 74 IAD Off Flag (IAOF)
88