English
Language : 

QB-RL78L1C Datasheet, PDF (27/42 Pages) Renesas Technology Corp – In-Circuit Emulator
QB-RL78L1C In-Circuit Emulator
CHAPTER 2 SETUP PROCEDURE
2.4 Connecting QB-RL78L1C to Target System
If connecting the emulation probe (QB-144-EP-02S), connect it to the QB-RL78L1C and the target system by the
following procedure.
(a) Connect the QB-RL78L1C to the probe.
Connect the emulation probe to the QB-RL78L1C, as shown below.
Insert CN1, CN2 and CN3 of the probe into TCN1, TCN2 and TCN3 of the QB-RL78L1C.
Insert the probe holder into QB-RL78L1C as below.
Figure 2-5. Connect the QB-RL78L1C to the probe
Probe holder
(b) Connection of emulation probe GND wire
There are three GND wires in the emulation probe. Connect them to the QB-RL78L1C and target system.
<1> Fasten the GND wire on the QB-RL78L1C side of the emulation probe to the nut on the bottom of
the QB-RL78L1C using a #0 or #1 Phillips precision screwdriver (connection of B to A in Figure 2-6).
<2> Next insert the connector on the top of the emulation probe into the connector at the opening on
the bottom of the QB-RL78L1C from below being careful of the insertion direction (connection of C in
Figure 2-6 to QB-RL78L1C).
R20UT2703EJ0200 Rev.2.00
Jan 31, 2014
Page 27 of 42